Yıl: 2013 Cilt: 43 Sayı: 1 Sayfa Aralığı: 18 - 21 Metin Dili: İngilizce İndeks Tarihi: 29-07-2022

Amount of lateral cortex loss in the femur while inserting a DHS-plate

Öz:
Aim: Although many anatomic, morphologic, and radiologic studies have been carried out for the femur as for all other bones of the skeletal system, we could not find any morphometric study to guide orthopedic surgeons on dynamic hip screw-plate (DHS-plate) applications of the proximal femur. Materials and methods: The lateral cortex width of 125 adult, dry, and grossly intact right and left cadaver femora was measured for the region of the femur in which the DHS-plate was applied, and the results were analyzed statistically. Results: The mean value of the proximal lateral cortex width of the femora was 27.63 mm. While inserting the DHS-plate, 45.24% of the mean width of the lateral cortex was lost. Conclusion: In this study we demonstrated the amount of lateral cortex loss in the femur while inserting a DHS-plate. New mechanical studies may be needed to show the amount of lateral cortex loss that leads to the fracture
Anahtar Kelime:

Konular: Cerrahi
Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
APA Aytekin M, Kucukdurmaz F, Esmer A, Sağlam N, Akpinar F (2013). Amount of lateral cortex loss in the femur while inserting a DHS-plate. , 18 - 21.
Chicago Aytekin Mahmut Nedim,Kucukdurmaz Fatih,Esmer Ali Firat,Sağlam Necdet,Akpinar Fuat Amount of lateral cortex loss in the femur while inserting a DHS-plate. (2013): 18 - 21.
MLA Aytekin Mahmut Nedim,Kucukdurmaz Fatih,Esmer Ali Firat,Sağlam Necdet,Akpinar Fuat Amount of lateral cortex loss in the femur while inserting a DHS-plate. , 2013, ss.18 - 21.
AMA Aytekin M,Kucukdurmaz F,Esmer A,Sağlam N,Akpinar F Amount of lateral cortex loss in the femur while inserting a DHS-plate. . 2013; 18 - 21.
Vancouver Aytekin M,Kucukdurmaz F,Esmer A,Sağlam N,Akpinar F Amount of lateral cortex loss in the femur while inserting a DHS-plate. . 2013; 18 - 21.
IEEE Aytekin M,Kucukdurmaz F,Esmer A,Sağlam N,Akpinar F "Amount of lateral cortex loss in the femur while inserting a DHS-plate." , ss.18 - 21, 2013.
ISNAD Aytekin, Mahmut Nedim vd. "Amount of lateral cortex loss in the femur while inserting a DHS-plate". (2013), 18-21.
APA Aytekin M, Kucukdurmaz F, Esmer A, Sağlam N, Akpinar F (2013). Amount of lateral cortex loss in the femur while inserting a DHS-plate. Turkish Journal of Medical Sciences, 43(1), 18 - 21.
Chicago Aytekin Mahmut Nedim,Kucukdurmaz Fatih,Esmer Ali Firat,Sağlam Necdet,Akpinar Fuat Amount of lateral cortex loss in the femur while inserting a DHS-plate. Turkish Journal of Medical Sciences 43, no.1 (2013): 18 - 21.
MLA Aytekin Mahmut Nedim,Kucukdurmaz Fatih,Esmer Ali Firat,Sağlam Necdet,Akpinar Fuat Amount of lateral cortex loss in the femur while inserting a DHS-plate. Turkish Journal of Medical Sciences, vol.43, no.1, 2013, ss.18 - 21.
AMA Aytekin M,Kucukdurmaz F,Esmer A,Sağlam N,Akpinar F Amount of lateral cortex loss in the femur while inserting a DHS-plate. Turkish Journal of Medical Sciences. 2013; 43(1): 18 - 21.
Vancouver Aytekin M,Kucukdurmaz F,Esmer A,Sağlam N,Akpinar F Amount of lateral cortex loss in the femur while inserting a DHS-plate. Turkish Journal of Medical Sciences. 2013; 43(1): 18 - 21.
IEEE Aytekin M,Kucukdurmaz F,Esmer A,Sağlam N,Akpinar F "Amount of lateral cortex loss in the femur while inserting a DHS-plate." Turkish Journal of Medical Sciences, 43, ss.18 - 21, 2013.
ISNAD Aytekin, Mahmut Nedim vd. "Amount of lateral cortex loss in the femur while inserting a DHS-plate". Turkish Journal of Medical Sciences 43/1 (2013), 18-21.