Yıl: 2017 Cilt: 23 Sayı: 2 Sayfa Aralığı: 137 - 143 Metin Dili: İngilizce İndeks Tarihi: 29-07-2022

Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies

Öz:
PURPOSE We aimed to evaluate the diagnostic accuracy and safety of computed tomography (CT)-guided biopsy of pulmonary lesions with fine needle aspiration (FNA) using non-coaxial technique.METHODSWe analyzed 442 patients who underwent CT-guided lung biopsy with FNA and non-coaxial technique to determine the diagnostic outcomes, complication rates, and independent risk fac-tors for diagnostic failure and pneumothorax.RESULTSDiagnostic accuracy, sensitivity, and specificity were 97.6%, 97.3%, and 100%, respectively. Age and >35 mm lesion size were significant risk factors for diagnostic failure. The rates of pneu-mothorax and chest tube placement were 19% and 2.9%, respectively. Middle and lower lobe location, lesion to pleura distance >7.5 mm, and >45° needle trajectory angle were significant risk factors for pneumothorax.CONCLUSIONCT-guided FNA of pulmonary lesions with non-coaxial technique is a safe and reliable method with a relatively low pneumothorax rate and an acceptably high diagnostic accuracy.
Anahtar Kelime:

Konular: Radyoloji, Nükleer Tıp, Tıbbi Görüntüleme
Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • Tsukada H, Satou T, Iwashima A, Souma T. Diag- nostic accuracy of CT-guided automated nee- dle biopsy of lung nodules. AJR Am J Roentge- nol 2000; 175:239-243. [CrossRef]
  • Hiraki T, Mimura H, Gobara H, et al. CT fluoros- copy-guided biopsy of 1,000 pulmonary le- sions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 2009; 136:1612-1617. [CrossRef]
  • Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishi- kawa T. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol 1996; 51:503-506. [CrossRef]
  • Takeshita J, Masago K, Kato R, et al. CT-guided fine-needle aspiration and core needle biop- sies of pulmonary lesions: a single-center ex- perience with 750 biopsies in Japan. AJR Am J Roentgenol 2015; 204:29-34. [CrossRef]
  • Yeow KM, Tsay PK, Cheung YC, Lui KW, Pan KT, Chou AS. Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol 2003; 14:581-588. [CrossRef]
  • Khan MF, Straub R, Moghaddam SR, et al. Vari- ables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided trans- thoracic biopsy. Eur Radiol 2008; 18:1356-1363. [CrossRef]
  • Covey AM, Gandhi R, Brody LA, Getrajdman G, Thaler HT, Brown KT. Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients. J Vasc Interv Radiol 2004; 15:479-483. [CrossRef]
  • Kuban JD, Tam AL, Huang SY, et al. The effect of needle gauge on the risk of pneumotho- rax and chest tube placement after percuta- neous computed tomographic (CT)-guided lung biopsy. Cardiovasc Intervent Radiol 2015; 38:1595-1602. [CrossRef]
  • Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic nee- dle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 2003; 229:475-481. [CrossRef]
  • Priola AM, Priola SM, Cataldi A, et al. Diagnostic accuracy and complication rate of CT-guided fine needle aspiration biopsy of lung lesions: a study based on the experience of the cytopathologist. Acta Radiol 2010; 51:527-533. [CrossRef]
  • Mullan CP, Kelly BE, Ellis PK, Hughes S, Anderson N, McCluggage WG. CT- guided fine-needle as- piration of lung nodules: effect on outcome of using coaxial technique and immediate cyto- logical evaluation. Ulster med J 2004; 73:32-36.
  • Hanley, J.A. and McNeil, B.J. The meaning and use of the area under a receiver operating charac- teristic (ROC) curve. Radiology 1983; 143:29-36. [CrossRef]
  • Wilber ST, Fu R. Risk ratios and odds ratios for common events in cross-sectional and cohort studies. Acad Emerg Med 2010; 17:649-651. [CrossRef]
  • Laurent F, Latrabe V, Vergier B, Michel P. Percuta- neous CT-guided biopsy of the lung: comparison between aspiration and automated cutting nee- dles using a coaxial technique. Cardiovasc Inter- vent Radiol 2000; 23:266-272. [CrossRef]
  • Montaudon M, Latrabe V, Pariente A, Corneloup O, Bequeret H, Laurent F. Factors influencing accu- racy of CT-guided percutaneous biopsies of pul- monary lesions. Eur Radiol 2004; 14:1234-1240. [CrossRef]
  • Klein JS, Salomon G, Stewart EA. Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 pa- tients. Radiology 1996; 198:715-720. [CrossRef]
  • Boiselle PM, Shepard JA, Mark EJ, et al. Routine addition of an automated biopsy device to fine-needle aspiration of the lung: a prospec- tive assessment. AJR Am J Roentgenol 1997; 169:661-666. [CrossRef]
  • Ohno Y, Hatabu H, Takenaka D, et al. CT-guided transthoracic needle aspiration biopsy of small (_____ or = 20 mm) solitary pulmonary nodules. AJR Am J Roentgenol 2003; 180:1665-1669. [CrossRef]
  • Cox JE, Chiles C, McManus CM, Aquino SL, Choplin RH. Transthoracic needle aspiration bi- opsy: variables that affect risk of pneumotho- rax. Radiology 1999; 212:165-168. [CrossRef]
  • Ko JP, Shepard JO, Drucker EA, et al. Factors influencing pneumothorax rate at lung biop- sy: are dwell time and angle of pleural punc- ture contributing factors? Radiology 2001; 218:491-496. [CrossRef]
  • Nour-Eldin NA, Alsubhi M, Emam A, et al. Pneu- mothorax complicating coaxial and non-coaxi- al CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients. Cardiovasc Intervent Radiol 2016; 39:261-270. [CrossRef]
  • Hiraki T, Mimura H, Gobara H, et al. Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective anal- ysis of the procedures conducted over a 9-year period. AJR Am J Roentgenol 2010; 194:809- 814. [CrossRef]
  • Saji H, Nakamura H, Tsuchida T, et al. The inci- dence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajecto- ry is a novel predictor. Chest 2002; 121:1521- 1526. [CrossRef]
  • Laurent F, Michel P, Latrabe V, Tunon de Lara M, Marthan R. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. AJR Am J Roentgenol 1999; 172:1049-1053. [CrossRef]
  • Yeow KM, Su IH, Pan KT, et al. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting nee- dle lung biopsies. Chest 2004; 126:748-754. [CrossRef]
APA Uzun Ç, Akkaya Z, DÜŞÜNCELİ ATMAN E, Üstüner E, PEKER E, Gulpinar B, ELHAN A, CEYHAN K, Atasoy C, TICLE O (2017). Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. , 137 - 143.
Chicago Uzun Çağlar,Akkaya Zehra,DÜŞÜNCELİ ATMAN EBRU,Üstüner Evren,PEKER Elif,Gulpinar Basak,ELHAN Atilla Halil,CEYHAN Koray,Atasoy Cetin,TICLE ORIGINAL AR Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. (2017): 137 - 143.
MLA Uzun Çağlar,Akkaya Zehra,DÜŞÜNCELİ ATMAN EBRU,Üstüner Evren,PEKER Elif,Gulpinar Basak,ELHAN Atilla Halil,CEYHAN Koray,Atasoy Cetin,TICLE ORIGINAL AR Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. , 2017, ss.137 - 143.
AMA Uzun Ç,Akkaya Z,DÜŞÜNCELİ ATMAN E,Üstüner E,PEKER E,Gulpinar B,ELHAN A,CEYHAN K,Atasoy C,TICLE O Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. . 2017; 137 - 143.
Vancouver Uzun Ç,Akkaya Z,DÜŞÜNCELİ ATMAN E,Üstüner E,PEKER E,Gulpinar B,ELHAN A,CEYHAN K,Atasoy C,TICLE O Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. . 2017; 137 - 143.
IEEE Uzun Ç,Akkaya Z,DÜŞÜNCELİ ATMAN E,Üstüner E,PEKER E,Gulpinar B,ELHAN A,CEYHAN K,Atasoy C,TICLE O "Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies." , ss.137 - 143, 2017.
ISNAD Uzun, Çağlar vd. "Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies". (2017), 137-143.
APA Uzun Ç, Akkaya Z, DÜŞÜNCELİ ATMAN E, Üstüner E, PEKER E, Gulpinar B, ELHAN A, CEYHAN K, Atasoy C, TICLE O (2017). Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. Diagnostic and Interventional Radiology, 23(2), 137 - 143.
Chicago Uzun Çağlar,Akkaya Zehra,DÜŞÜNCELİ ATMAN EBRU,Üstüner Evren,PEKER Elif,Gulpinar Basak,ELHAN Atilla Halil,CEYHAN Koray,Atasoy Cetin,TICLE ORIGINAL AR Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. Diagnostic and Interventional Radiology 23, no.2 (2017): 137 - 143.
MLA Uzun Çağlar,Akkaya Zehra,DÜŞÜNCELİ ATMAN EBRU,Üstüner Evren,PEKER Elif,Gulpinar Basak,ELHAN Atilla Halil,CEYHAN Koray,Atasoy Cetin,TICLE ORIGINAL AR Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. Diagnostic and Interventional Radiology, vol.23, no.2, 2017, ss.137 - 143.
AMA Uzun Ç,Akkaya Z,DÜŞÜNCELİ ATMAN E,Üstüner E,PEKER E,Gulpinar B,ELHAN A,CEYHAN K,Atasoy C,TICLE O Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. Diagnostic and Interventional Radiology. 2017; 23(2): 137 - 143.
Vancouver Uzun Ç,Akkaya Z,DÜŞÜNCELİ ATMAN E,Üstüner E,PEKER E,Gulpinar B,ELHAN A,CEYHAN K,Atasoy C,TICLE O Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies. Diagnostic and Interventional Radiology. 2017; 23(2): 137 - 143.
IEEE Uzun Ç,Akkaya Z,DÜŞÜNCELİ ATMAN E,Üstüner E,PEKER E,Gulpinar B,ELHAN A,CEYHAN K,Atasoy C,TICLE O "Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies." Diagnostic and Interventional Radiology, 23, ss.137 - 143, 2017.
ISNAD Uzun, Çağlar vd. "Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies". Diagnostic and Interventional Radiology 23/2 (2017), 137-143.