Yıl: 2014 Cilt: 48 Sayı: 4 Sayfa Aralığı: 443 - 448 Metin Dili: İngilizce İndeks Tarihi: 29-07-2022

Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability

Öz:
Objective: The aim of this study was to evaluate the clinical and radiologic results of the use of thick spiral silk knotting instead of sublaminar wiring for C1-C2 arthrodesis in patients with atlantoaxial instability.Methods: We retrospectively evaluated 16 patients (10 females, 6 males; mean age: 43.4 years; mean follow-up: 34 months) with atlantoaxial instability who underwent C1-C2 fusion by reduction and sublaminar spiral silk knotting. All patients underwent open reduction, bounding both laminae with thick spiral silk instead of wiring and arthrodesis with autografting. Reduction rates, screw position and fusion rates were evaluated using computed tomography.Results: Preoperative mean atlantodental interval (ADI) was 8 (range: 6 to 11) mm and postoperative ADI was 2.1 (range: 0.5 to 2.5) mm. There was no dural or spinal cord injury. Complete reduction was observed in all cases. Fusion was unsuccessful in 1 case (6.25%). Postoperative mean flexion ADI was 10 mm and mean extension ADI was 1 mm. Graft separation between C1-C2 was observed in slice tomographic examination in one patient. Malposition was observed in 2 screws (4%).Conclusion: The sublaminar silk knotting technique appears to provide safe anatomical reduction. As this method is cheap and simple and does not require extra implantation, loosen, create neurologic compromise or cause radiologic crowding, it can be considered an alternative surgical technique to sublaminar wiring.
Anahtar Kelime:

Konular: Cerrahi
Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Bibliyografik
  • Kotil K, Kalayci M, Bilge T. Management of cervicome- dullary compression in patients with congenital and ac- quired osseous-ligamentous pathologies. J Clin Neurosci 2007;14:540-9.
  • Kotil K, Köksal NS, Kayacı S. Posterior transodontoid fixation: A new fixation (Kotil) technique. J Craniovertebr Junction Spine 2011;2:41-5.
  • Dickman CA, Sonntag VK. Posterior C1-C2 transarticu- lar screw fixation for atlantoaxial arthrodesis. Neurosur- gery 1998;43:275-81.
  • Gluf WM, Brockmeyer DL. Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients. J Neurosurg Spine 2005;2:164-9.
  • Gluf WM, Schmidt MH, Apfelbaum RI. Atlantoaxial transarticular screw fixation: a review of surgical indica- tions, fusion rate, complications, and lessons learned in 191 adult patients. J Neurosurg Spine 2005;2:155-63.
  • Paramore CG, Dickman CA, Sonntag VK. The anatomi- cal suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 1996;85:221-4.
  • Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 1997;86:961-8.
  • Melcher RP, Puttlitz CM, Kleinstueck FS, Lotz JC, Harms J, Bradford DS. Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 2002;27:2435-40.
  • Gallie WE. Fracture and dislocations of the cervical spine. Am J Surg 1939;46:495-9.
  • Fraser AB, Sen C, Casden AM, Catalano PJ, Post KD. Cervical transdural intramedullary migration of a sub- laminar wire. A complication of cervical fixation. Spine 1994;19:456-9.
  • Geremia GK, Kim KS, Cerullo L, Calenoff L. Complica- tions of sublaminar wiring. Surg Neurol 1985;23:629-35.
  • Lundy DW, Murray HH. Neurological deterioration after posterior wiring of the cervical spine. J Bone Joint Surg Br 1997;79:948-51.
  • Schrader WC, Bethem D, Scerbin V. The chronic lo- cal effects of sublaminar wires. An animal model. Spine 1988;13:499-502.
  • Kakarla UK, Valdivia JV, Sonntag VK, Bambakidis NC. Intracranial hemorrhage and spinal cord injury from a fractured C1-C2 sublaminar cable: case report. Neurosur- gery 2010;66:E1203-4.
  • Grob D, Crisco JJ 3rd, Panjabi MM, Wang P, Dvorak J. Biomechanical evaluation of four different posterior atlan- toaxial fixation techniques. Spine 1992;17:480-90.
  • Harms J, Melcher RP. Posterior C1-C2 fusion with poly- axial screw and rod fixation. Spine 2001;26:2467-71.
  • Henriques T, Cunningham BW, Olerud C, Shimamoto N, Lee GA, Larsson S, et al. Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine 2000;25:2877-83.
  • Lapsiwala SB, Anderson PA, Oza A, Resnick DK. Biome- chanical comparison of four C1 to C2 rigid fixative tech- niques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neuro- surgery 2006;58:516-21.
  • Matsumoto M, Chiba K, Nakamura M, Ogawa Y, Toyama Y, Ogawa J. Impact of interlaminar graft materials on the fusion status in atlantoaxial transarticular screw fixation. J Neurosurg Spine 2005;2:23-6.
  • Garcia R Jr, Gorin S. Failure of posterior titanium atlanto- axial cable fixation. Spine J 2003;3:166-70.
  • Bahadur R, Goyal T, Dhatt SS, Tripathy SK. Transar- ticular screw fixation for atlantoaxial instability - modi- fied Magerl's technique in 38 patients. J Orthop Surg Res 2010;5:87.
  • Ito T, Hayashi M, Takei H. Loosening of supplemental cable in transarticular screw fixation and bone grafting. J Orthop Surg 1998;6:71-4.
  • Ito H, Neo M, Fujibayashi S, Miyata M, Yoshitomi H, Nakamura T. Atlantoaxial transarticular screw fixation with posterior wiring using polyethylene cable: facet fu- sion despite posterior graft resorption in rheumatoid pa- tients. Spine 2008;33:1655-61.
  • Stillerman CB, Wilson JA. Atlanto-axial stabilization with posterior transarticular screw fixation: technical descrip- tion and report of 22 cases. Neurosurgery 1993;32:948- 55.
APA KOTİL k, GÖKHAN BİLGİLİ M, KAYACI S (2014). Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. , 443 - 448.
Chicago KOTİL kadir,GÖKHAN BİLGİLİ Mustafa,KAYACI Selim Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. (2014): 443 - 448.
MLA KOTİL kadir,GÖKHAN BİLGİLİ Mustafa,KAYACI Selim Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. , 2014, ss.443 - 448.
AMA KOTİL k,GÖKHAN BİLGİLİ M,KAYACI S Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. . 2014; 443 - 448.
Vancouver KOTİL k,GÖKHAN BİLGİLİ M,KAYACI S Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. . 2014; 443 - 448.
IEEE KOTİL k,GÖKHAN BİLGİLİ M,KAYACI S "Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability." , ss.443 - 448, 2014.
ISNAD KOTİL, kadir vd. "Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability". (2014), 443-448.
APA KOTİL k, GÖKHAN BİLGİLİ M, KAYACI S (2014). Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. Acta Orthopaedica et Traumatologica Turcica, 48(4), 443 - 448.
Chicago KOTİL kadir,GÖKHAN BİLGİLİ Mustafa,KAYACI Selim Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. Acta Orthopaedica et Traumatologica Turcica 48, no.4 (2014): 443 - 448.
MLA KOTİL kadir,GÖKHAN BİLGİLİ Mustafa,KAYACI Selim Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. Acta Orthopaedica et Traumatologica Turcica, vol.48, no.4, 2014, ss.443 - 448.
AMA KOTİL k,GÖKHAN BİLGİLİ M,KAYACI S Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. Acta Orthopaedica et Traumatologica Turcica. 2014; 48(4): 443 - 448.
Vancouver KOTİL k,GÖKHAN BİLGİLİ M,KAYACI S Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability. Acta Orthopaedica et Traumatologica Turcica. 2014; 48(4): 443 - 448.
IEEE KOTİL k,GÖKHAN BİLGİLİ M,KAYACI S "Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability." Acta Orthopaedica et Traumatologica Turcica, 48, ss.443 - 448, 2014.
ISNAD KOTİL, kadir vd. "Reduction and arthrodesis with sublaminar spiral silk in atlantoaxial joint instability". Acta Orthopaedica et Traumatologica Turcica 48/4 (2014), 443-448.