Öz:
Objective: The aim of this study was to propose a new computer based method for measuring acetabularangles on hip radiographs and to assess its practicality, sensitivity and reliability for acetabular anglemeasurement.Methods: A total of 314 acetabulum were assessed on 157 pelvic X-ray images. Acetabular angles weremeasured with both the conventional method (Method 1) and our proposed method (Method 2). All theAcetabular Index (AI) angle, Acetabular Angle (AA) and Acetabular Center (ACM) angle were measuredwith both methods.Results: The mean AI angle for Method 1 is 11.02± 2.7and the mean AI angle for Method 2 is10.08± 1.88, the mean AA angle for Method 1 is 39.5± 5.3and the mean AA angle for Method 2 is39.36± 4.68, the mean ACM angle for Method 1 is 50.5± 6.01and the mean ACM angle for Method 2is 55.42± 12.43.Conclusion: Our novel automated method appear to be reliable and practical for acetabular anglemeasurement on hip radiographs.Level of Evidence: Level III, Diagnostic study© 2017 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V. This isan open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Anahtar Kelime:

Konular: Cerrahi
Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Bibliyografik
  • Campbell SE. Radiography of the hip: lines, signs, and patterns of disease. Semin Roentgenol. 2005;40:290e319.
  • Swagerty Jr DL, Hellinger D. Radiographic assessment of osteoarthritis. Am Fam Physician. 2001;64:279e286.
  • Goker B, Gonen E, Demirag MD, Block JA. QuantiŞcation of the radiographic joint space width of the ankle. Clin Orthop Relat Res. 2009;467:2083e2089.
  • Tonnis D. Normal values of the hip joint for the evaluation of X-rays in children and adults. Clin Orthop Relat Res. 1976:39e47.
  • Sharp I. Acetabular dysplasia. The acetabular angle. J Bone Jt Surg [Br]. 1961;43: 268e272.
  • Idelberger K, Frank A. Uber eine neue Methode zur Bestimmung des Pfan- nendachwinkels beim Jugendlichen und Erwachsenen (in German). Z Orthop. 1952;82:571e577.
  • Lee YK, Chung CY, Koo KH, Lee KM, Kwon DG, Park MS. Measuring acetabular dysplasia in plain radiographs. Arch Orthop Trauma Surg. 2011;131:1219e1226.
  • Al-Bashir AK, Al-Abed M, Abu Sharkh FM, Kordeya MN, Rousan FM. Algorithm for automatic angles measurement and screening for Developmental Dysplasia of the Hip (DDH). In: Conference Proceedings:...Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference 2015. 2015:6386e6389.
  • Clohisy JC, Carlisle JC, Beaule PE, et al. A systematic approach to the plain radiographic evaluation of the young adult hip. Journal Bone Jt Surg. American Volume. 2008;90(4):47e66.
  • Conrozier T, Brandt K, Piperno M, Mathieu P, Merle-Vincent F, Vignon E. Reproducibility and sensitivity to change of a new method of computer mea- surement of joint space width in hip osteoarthritis. Performance of three radiographic views obtained at a 3-year interval. Osteoarthr Cartilage/OARS Osteoarthr Res Soc. 2009;17:864e870.
  • Engesaeter IO, Laborie LB, Lehmann TG, et al. RadiologicalŞndings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques. Skelet Radiol. 2012;41:775e785.
  • Nagao Y, Aoki H, Ishii SJ, Masuda T, Beppu M. Radiographic method to measure the inclination angle of the acetabulum. J Orthop Sci: OfŞcial Journal of the Japanese Orthopaedic Association. 2008;13:62e71.
  • Pedersen DR, Lamb CA, Dolan LA, Ralston HM, Weinstein SL, Morcuende JA. Radiographic measurements in developmental dysplasia of the hip: reliability and validity of a digitizing program. J Pediatr Orthop. 2004;24:156e160.
  • van der List JP, Witbreuk MM, Buizer AI, van der Sluijs JA. The prognostic value of the head-shaft angle on hip displacement in children with cerebral palsy. J Children's Orthop. 2015;9:129e135.
  • Agus H, Bicimoglu A, Omeroglu H, Tumer Y. How should the acetabular angle of Sharp be measured on a pelvic radiograph? J Pediatr Orthop. 2002;22:228e231.
  • Ozcelik A, Omeroglu H, Inan U, Ozyurt B, Seber S. Normal values of several acetabular angles on hip radiographs obtained from individuals living in the Eskisehir region. Acta Orthop Traumatol Turc. 2002;36:100e105.
  • Boniforti FG, Fujii G, Angliss RD, Benson MK. The reliability of measurements of pelvic radiographs in infants. J Bone Jt Surg. British Volume. 1997;79:570e575.
  • Mast NH, Impellizzeri F, Keller S, Leunig M. Reliability and agreement of measures used in radiographic evaluation of the adult hip. Clin Orthop Relat Res. 2011;469:188e199.
  • Radermacher K, Portheine F, Anton M, et al. Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res. 1998: 28e38.
  • Tanure MC, Pinheiro AP, Oliveira AS. Reliability assessment of Cobb angle measurements using manual and digital methods. Spine J OfŞcial J North Am Spine Soc. 2010;10:769e774.
  • Bouttier R, Morvan J, Mazieres B, et al. Reproducibility of radiographic hip measurements in adults. Jt Bone Spine Rev Rhum. 2013;80:52e56.
  • Terjesen T, Gunderson RB. Reliability of radiographic parameters in adults with hip dysplasia. Skelet Radiol. 2012;41:811e816.
  • Nelitz M, Guenther KP, Gunkel S, Puhl W. Reliability of radiological measure- ments in the assessment of hip dysplasia in adults. Br J Radiol. 1999;72: 331e334.
  • Kay RM, Watts HG, Dorey FJ. Variability in the assessment of acetabular index. J Pediatr Orthop. 1997;17:170e173.
  • Arenson RL, Andriole KP, Avrin DE, Gould RG. Computers in imaging and health care: now and in the future. J Digit Imaging. 2000;13:145e156.
APA Şahin S, AKATA M, Sahin O, tuncay i, Özkan H (2017). A novel computer-based method for measuring the acetabular angle on hip radiographs. , 155 - 159.
Chicago Şahin Seda,AKATA MURAT EMİN,Sahin Orcun,tuncay ismail cengiz,Özkan Hüseyin A novel computer-based method for measuring the acetabular angle on hip radiographs. (2017): 155 - 159.
MLA Şahin Seda,AKATA MURAT EMİN,Sahin Orcun,tuncay ismail cengiz,Özkan Hüseyin A novel computer-based method for measuring the acetabular angle on hip radiographs. , 2017, ss.155 - 159.
AMA Şahin S,AKATA M,Sahin O,tuncay i,Özkan H A novel computer-based method for measuring the acetabular angle on hip radiographs. . 2017; 155 - 159.
Vancouver Şahin S,AKATA M,Sahin O,tuncay i,Özkan H A novel computer-based method for measuring the acetabular angle on hip radiographs. . 2017; 155 - 159.
IEEE Şahin S,AKATA M,Sahin O,tuncay i,Özkan H "A novel computer-based method for measuring the acetabular angle on hip radiographs." , ss.155 - 159, 2017.
ISNAD Şahin, Seda vd. "A novel computer-based method for measuring the acetabular angle on hip radiographs". (2017), 155-159.
APA Şahin S, AKATA M, Sahin O, tuncay i, Özkan H (2017). A novel computer-based method for measuring the acetabular angle on hip radiographs. Acta Orthopaedica et Traumatologica Turcica, 51(2), 155 - 159.
Chicago Şahin Seda,AKATA MURAT EMİN,Sahin Orcun,tuncay ismail cengiz,Özkan Hüseyin A novel computer-based method for measuring the acetabular angle on hip radiographs. Acta Orthopaedica et Traumatologica Turcica 51, no.2 (2017): 155 - 159.
MLA Şahin Seda,AKATA MURAT EMİN,Sahin Orcun,tuncay ismail cengiz,Özkan Hüseyin A novel computer-based method for measuring the acetabular angle on hip radiographs. Acta Orthopaedica et Traumatologica Turcica, vol.51, no.2, 2017, ss.155 - 159.
AMA Şahin S,AKATA M,Sahin O,tuncay i,Özkan H A novel computer-based method for measuring the acetabular angle on hip radiographs. Acta Orthopaedica et Traumatologica Turcica. 2017; 51(2): 155 - 159.
Vancouver Şahin S,AKATA M,Sahin O,tuncay i,Özkan H A novel computer-based method for measuring the acetabular angle on hip radiographs. Acta Orthopaedica et Traumatologica Turcica. 2017; 51(2): 155 - 159.
IEEE Şahin S,AKATA M,Sahin O,tuncay i,Özkan H "A novel computer-based method for measuring the acetabular angle on hip radiographs." Acta Orthopaedica et Traumatologica Turcica, 51, ss.155 - 159, 2017.
ISNAD Şahin, Seda vd. "A novel computer-based method for measuring the acetabular angle on hip radiographs". Acta Orthopaedica et Traumatologica Turcica 51/2 (2017), 155-159.