Evaluation of H-800/FUS-100 automatic urine analyzer performance

Öz:
Objective: Automated urine analysis is usually preferredfor laboratories with intensive workload. The aim ofthis study was to evaluate the performance of the automatedurine analyser H-800/FUS-100 and detect the errorsources.Materials and methods: One thousand four hundredfifty nine fresh urine samples were analyzed with H-800/FUS-100 automated systems. The urine sediment of thesamples with discrepant strip and microscopy resultswere confirmed by manual microscopy. Precision andcarry over studies were performed.Results: The discrepancy is detected in a ratio of 5.89%between chemical analysis (H-800) and microscopicanalysis (FUS-100) of the device. A total of 86 discrepantsamples were detected. Fifty six of 86 were erythrocytediscrepancies (65.1%) and 30 of 86 were leukocytediscrepancies (34.9%). The results of carry over analysisfor erythrocyte and leukocyte were 21.85% and 13.64%,respectively.Conclusions: Sixteen (1.09%) of 1459 patients’ results inFUS-100 were discrepant with manual microscopy. Commonly,yeasts and crystals affected erythrocyte countsand calcium oxalate and amorphous crystals affected theleukocyte counts. Images should be reviewed for everysample when automated systems are used for urine analysis.Especially if discrepancy is detected between chemicaland microscobic analysis, the results should also beconfirmed with manual microscopy.
Anahtar Kelime:

Konular: Diş Hekimliği Toksikoloji Biyokimya ve Moleküler Biyoloji Farmakoloji ve Eczacılık

H-800/FUS-100 otomatİk İdrar analİzörün performans değerlendİrİlmesİ

Öz:
Amaç: Otomatik idrar analizi genellikle yoğun iş yükü olan laboratuvarlarda tercih edilmektedir. Çalışmamızda, H-800/FUS-100 otomatik idrar cihazının performansının değerlendirilmesi ve hata kaynaklarının saptanması amaçlanmıştır. Gereç ve yöntem: 1459 taze idrar örnekleri H-800/FUS-100 otomatize sisteminde çalışılmıştır. Uyumsuz strip ve mikroskobi sonuçları olan idrar sediment örnekleri manuel mikroskobi ile teyit edilmiştir. Presizyon ve carry-over çalışmaları yapılmıştır. Bulgular: Cihazın kimyasal analizi (H-800) ile mikroskobik analizi (FUS-100) arasında %5.89 oranında bir uyumsuzluk saptanmıştır. Saptanan 86 olgunun 56’sında eritrosit (%65.1), 30’unda lökosit (%34.9) uyumsuzluğu tespit edilmiştir. Eritrosit ve lökosit için carry-over çalışmasının sonuçları sırasıyla %21.85 ve %13.64 olarak bulunmuştur. Sonuç: 1459 hasta sonucundan 16 tanesinde (%1.09) manuel mikroskopi ile uyumsuzluk saptanmıştır. Eritrositler için kristaller ve mayaların, lökositler için kalsiyum oksalat ve amorf kristallerinin sayıları etkilediği gözlenmiştir. İdrar analizinde otomatize sistemler kullanıldığında her örnek için görüntüler gözden geçirilmelidir. Özellikle kimyasal ve mikroskopik analiz arasında uyumsuzluk saptandığında, sonuçlar manuel mikroskopi ile teyit edilmelidir.
Anahtar Kelime:

Konular: Diş Hekimliği Toksikoloji Biyokimya ve Moleküler Biyoloji Farmakoloji ve Eczacılık
Belge Türü: Makale Makale Türü: Diğer Erişim Türü: Erişime Açık
  • 1. Gadeholt H. Quantitative estimation of urinary sediment, with special regard to sources of error. Br Med J 1964;1:1547–9.
  • 2. Winkel P, Statland BE, Jorgensen K. Urine microscopy, an illdefined method, examined by a multifactorial technique. Clin Chem 1974;20:436–9.
  • 3. European urinalysis guidelines. Scand J Clin Lab Invest Suppl 2000;231:1–86.
  • 4. Urinalysis and collection, transportation and preservation of urine specimens; approved guideline. National Committee for Clinical Laboratory Standards. Wayne, PA, USA (NCCLS document GP 16-A), 1995.
  • 5. Clemens AH, Hurtle RL. Automatic system for urine analysis. I. System design and development. Clin Chem 1972;18:789–93.
  • 6. Chien TI, Kao JT, Liu HL, Lin PC, Hong JS, Hsieh HP, et al. Urine sediment examination: a comparison of automated urinalysis systems and manual microscopy. Clin Chim Acta 2007;384:28–34.
  • 7. Hyodo T, Kumano K, Haga M, Sakai T. [Detection of glomerular and non-glomerular red blood cells by automated urinary sediment analyzer]. Nihon Jinzo Gakkai Shi 1995;37:35–43.
  • 8. Deindoerfer FH, Gangwer JR, Laird CW, Ringold RR. “The Yellow IRIS” urinalysis workstation–the first commercial application of “automated intelligent microscopy”. Clin Chem 1985;31:1491–9.
  • 9. Okada H, Sakai Y, Kawabata G, Fujisawa M, Arakawa S, Hamaguchi Y, et al. Automated urinalysis. Evaluation of the Sysmex UF-50. Am J Clin Pathol 2001;115:605–10.
  • 10. Özcan O, Bitigiç M, Yücel D. Investigation of possible error sources in urinalysis performed by urisys 2400/sysmex UF 100. Turk J Biochem 2010;35:230–5.
APA ERCAN KARADAĞ M, FIRAT OĞUZ E, KAYA O, Yılmaz F (2018). Evaluation of H-800/FUS-100 automatic urine analyzer performance. , 89 - 92. 10.1515/tjb-2016-0248
Chicago ERCAN KARADAĞ MÜJGAN,FIRAT OĞUZ Esra,KAYA Oğuzhan,Yılmaz Fatma Meriç Evaluation of H-800/FUS-100 automatic urine analyzer performance. (2018): 89 - 92. 10.1515/tjb-2016-0248
MLA ERCAN KARADAĞ MÜJGAN,FIRAT OĞUZ Esra,KAYA Oğuzhan,Yılmaz Fatma Meriç Evaluation of H-800/FUS-100 automatic urine analyzer performance. , 2018, ss.89 - 92. 10.1515/tjb-2016-0248
AMA ERCAN KARADAĞ M,FIRAT OĞUZ E,KAYA O,Yılmaz F Evaluation of H-800/FUS-100 automatic urine analyzer performance. . 2018; 89 - 92. 10.1515/tjb-2016-0248
Vancouver ERCAN KARADAĞ M,FIRAT OĞUZ E,KAYA O,Yılmaz F Evaluation of H-800/FUS-100 automatic urine analyzer performance. . 2018; 89 - 92. 10.1515/tjb-2016-0248
IEEE ERCAN KARADAĞ M,FIRAT OĞUZ E,KAYA O,Yılmaz F "Evaluation of H-800/FUS-100 automatic urine analyzer performance." , ss.89 - 92, 2018. 10.1515/tjb-2016-0248
ISNAD ERCAN KARADAĞ, MÜJGAN vd. "Evaluation of H-800/FUS-100 automatic urine analyzer performance". (2018), 89-92. https://doi.org/10.1515/tjb-2016-0248
APA ERCAN KARADAĞ M, FIRAT OĞUZ E, KAYA O, Yılmaz F (2018). Evaluation of H-800/FUS-100 automatic urine analyzer performance. Türk Biyokimya Dergisi, 43(1), 89 - 92. 10.1515/tjb-2016-0248
Chicago ERCAN KARADAĞ MÜJGAN,FIRAT OĞUZ Esra,KAYA Oğuzhan,Yılmaz Fatma Meriç Evaluation of H-800/FUS-100 automatic urine analyzer performance. Türk Biyokimya Dergisi 43, no.1 (2018): 89 - 92. 10.1515/tjb-2016-0248
MLA ERCAN KARADAĞ MÜJGAN,FIRAT OĞUZ Esra,KAYA Oğuzhan,Yılmaz Fatma Meriç Evaluation of H-800/FUS-100 automatic urine analyzer performance. Türk Biyokimya Dergisi, vol.43, no.1, 2018, ss.89 - 92. 10.1515/tjb-2016-0248
AMA ERCAN KARADAĞ M,FIRAT OĞUZ E,KAYA O,Yılmaz F Evaluation of H-800/FUS-100 automatic urine analyzer performance. Türk Biyokimya Dergisi. 2018; 43(1): 89 - 92. 10.1515/tjb-2016-0248
Vancouver ERCAN KARADAĞ M,FIRAT OĞUZ E,KAYA O,Yılmaz F Evaluation of H-800/FUS-100 automatic urine analyzer performance. Türk Biyokimya Dergisi. 2018; 43(1): 89 - 92. 10.1515/tjb-2016-0248
IEEE ERCAN KARADAĞ M,FIRAT OĞUZ E,KAYA O,Yılmaz F "Evaluation of H-800/FUS-100 automatic urine analyzer performance." Türk Biyokimya Dergisi, 43, ss.89 - 92, 2018. 10.1515/tjb-2016-0248
ISNAD ERCAN KARADAĞ, MÜJGAN vd. "Evaluation of H-800/FUS-100 automatic urine analyzer performance". Türk Biyokimya Dergisi 43/1 (2018), 89-92. https://doi.org/10.1515/tjb-2016-0248