Yıl: 2020 Cilt: 26 Sayı: 2 Sayfa Aralığı: 178 - 185 Metin Dili: İngilizce DOI: 10.14744/tjtes.2019.72627 İndeks Tarihi: 05-10-2020

A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy

Öz:
ABSTRACTBACKGROUND: The present study aims to investigate the usefulness of NIRS in identifying decreased blood flow in intestinal tissue inside the hernial sac in incarcerated hernias.METHODS: Forty patients with manually irreducible inguinal hernias and with ileus determined by clinical findings and imaging were included in this study. Patients’ intestinal oxygenatıons were measured by placing NIRS probes over the areas of inguinal hernia and over non-herniated areas immediately lateral to these. Differences in oxygenation between normal and herniated areas were evaluated.RESULTS: Forty patients, 14 women (35.0%) and 26 (65.0%) men, with a mean age of 65±14, were enrolled in this study. Intestinal oxygenation was lower in areas of irreducible hernia compared to normal regions (p<0.001). Incarceration and/or strangulation were detected when hernial sacs with low intestinal oxygenation were operated on. Low NIRS measurements were able to identify incarceration and/or strangulation in the intestine but were unable to distinguish between them.CONCLUSION: In conclusion, in the light of the findings of this study, although not capable of differentiating incarceration from strangulation, NIRS appears to be a good method for showing impaired intestinal oxygenation. NIRS can be used to support ultrasonography findings in irreducible hernias. Therefore, this technique could be used in the future to evaluate and monitor intestinal oxygenation in the Emergency Department.
Anahtar Kelime:

Strangüle ve inkarsere hernilerin değerlendirilmesinde yeni bir teknik: Near infrared spectroscopy

Öz:
AMAÇ: Bu çalışmamızın amacı, redükte edilemeyen inguinal hernilerde bağırsak oksijenizasyonunu değerlendirmek için yeni bir yöntem olan near infrared spektrofotometri (NIR) spektroskopi tekniğini kullanmaktır. Böylece erken dönemde bağırsak oksijenizasyonu hakkında bilgi edinmeyi ve NIRS’nin kullanılabilirliğini değerlendirmeyi amaçladık.GEREÇ VE YÖNTEM: Çalışmamıza inguinal hernileri olup elle redükte edilemeyen ve klinik bulgu ve görüntüleme yöntemleri ile ileus tespit edilen 40 hasta alındı. Hastaların inguninal herni olan bölgeleri ile tam lateralinde herni olmayan bölgelerine NIRS propları yapıştırılarak bağırsak oksijenizasyonları ölçüldü. Normal ve herni olan bölgeler arasındaki oksijenizasyon farkları değerlendirildi.BULGULAR: Yaş ortalaması 65±14 olan, 14’ü kadın (%35.0) ve 26’sı erkek (%65.0) toplam 40 hasta bu çalışmaya alındı. Hastaların redükte edilemeyen herni bölgesinde bağırsak oksijenizasyonları normal bölgelerine göre düşüktü (p<0.001). Bağırsak oksijenizasyonları düşük olan inguinal herni keseleri ameliyat edildiğinde inkarserasyon ve/veya strangülasyon tespit edildi. NIRS ölçümlerinin düşük ölçülmesi bağırsaktaki inkarserasyon ve/ veya strangülasyonu tespit edebiliyordu fakat ikisi birbirinden ayırt edilemiyordu.TARTIŞMA: Bu çalışmanın bulguları ışığında, strangülasyondan hapsedilmeyi ayırt edememesine rağmen, NIRS bozulmuş bağırsak oksijenasyonu için iyi bir yöntem olarak görünmektedir. NIRS, indirgenemez fıtıklarda ultrasonografi bulgularını desteklemek için kullanılabilir. Bu nedenle, gelecekte acil serviste bağırsak oksijenasyonunu değerlendirmek ve izlemek için bu teknik kullanılabilir
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Derici H, Unalp HR, Nazli O, Kamer E, Coskun M, Tansug T, et al. Prosthetic repair of incarcerated inguinal hernias: is it a reliable method? Langenbecks Arch Surg 2010;395:575−9.
  • 2. Kalkan A, Bilir O, Ersunan G, Ozel D, Tas M, Memetoglu ME. Abdominal oxygen saturation for monitoring return of spontaneous circulation in out-of-hospital cardiac arrest using near infrared spectrophometry. Am J Emerg Med 2015;33:344–8.
  • 3. DeWitt AG, Charpie JR, Donohue JE, Yu S, Owens GE. Splanchnic near-infrared spectroscopy and risk of necrotizing enterocolitis after neonatal heart surgery. Pediatr Cardiol 2014;35:1286–94.
  • 4. Meng L, Gelb AW, Alexander BS, Cerussi AE, Tromberg BJ, Yu Z, et al. Impact of phenylephrine administration on cerebral tissue oxygen saturation and blood volume is modulated by carbon dioxide in anaesthetized patients. Br J Anaesth 2012;108:815−22.
  • 5. Asim K, Ozlem B, Gokhan E, Zihni Y, Deniz O, Mahmut T, et al. The Use of Cerebral Oximetry in Acute Carbon Monoxide Intoxication: A Preliminary Study. Keio J Med 2015;64:57−61.
  • 6. Asim K, Gokhan E, Ozlem B, Ozcan Y, Deniz O, Kamil K, et al. Near infrared spectrophotometry (cerebral oximetry) in predicting the return of spontaneous circulation in out-of-hospital cardiac arrest. Am J Emerg Med 2014;32:14−7.
  • 7. Gay AN, Lazar DA, Stoll B, Naik-Mathuria B, Mushin OP, Rodriguez MA, et al. Near-infrared spectroscopy measurement of abdominal tissue oxygenation is a useful indicator of intestinal blood flow and necrotizing enterocolitis in premature piglets. J Pediatr Surg 2011;46:1034−40.
  • 8. Cortez J, Gupta M, Amaram A, Pizzino J, Sawhney M, Sood BG. Noninvasive evaluation of splanchnic tissue oxygenation using near-infrared spectroscopy in preterm neonates. J Matern Fetal Neonatal Med 2011;24:574–82.
  • 9. Dani C, Pratesi S, Barp J, Bertini G, Gozzini E, Mele L, et al. Near-infrared spectroscopy measurements of splanchnic tissue oxygenation during continuous versus intermittent feeding method in preterm infants. J Pediatr Gastroenterol Nutr 2013;56:652−6.
  • 10. Bozzetti V, Paterlini G, Meroni V, DeLorenzo P, Gazzolo D, Van Bel F, et al. Evaluation of splanchnic oximetry, Doppler flow velocimetry in the superior mesenteric artery and feeding tolerance in very low birth weight IUGR and non-IUGR infants receiving bolus versus continuous enteral nutrition. BMC Pediatr 2012;12:106.
  • 11. Ersunan G, Bilir O, Kalkan A, Kalkan Y, Ozel D, Kayayurt K, et al. Utility of near infrared spectrophotometry in mesenteric ischemia: an experimental study. J Near Infrared Spectroscopy August 4, 2018.
  • 12. Kim B, Robinson P, Modi H, Gupta H, Horgan K, Achuthan R. Evaluation of the usage and influence of groin ultrasound in primary and secondary healthcare settings. Hernia 2015;19:367–71.
  • 13. Kraft BM, Kolb H, Kuckuk B, Haaga S, Leibl BJ, Kraft K, et al. Diagnosis and classification of inguinal hernias. Surg Endosc 2003;17:2021−4.
  • hernia with physical examination, ultrasound, and MRI compared with laparoscopic findings. Invest Radiol 1999;34:739–43.
  • 14. van den Berg JC, de Valois JC, Go PM, Rosenbusch G. Detection of groin hernia with physical examination, ultrasound, and MRI compared with laparoscopic findings. Invest Radiol 1999;34:739–43
  • 15. Torricelli A, Contini D, Dalla Mora A, Pifferi A, Re R, et al. Neurophotonics: non-invasive optical techniques for monitoring brain functions. Funct Neurol 2014;29:223−30.
  • 16. Ferrari M, Quaresima V. A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of application. Neuroimage 2012;63:921–35.
  • 17. Arridge SR. Optical tomography in medical imaging. Inverse Problems 1999;15:R41−93.
  • 18. Leff DR, Orihuela-Espina F, Elwell CE, Athanasiou T, Delpy DT, Darzi AW, et al. Assessment of the cerebral cortex during motor task behaviours in adults: a systematic review of functional near infrared spectroscopy (fNIRS) studies. Neuroimage 2011;54:2922−36.
  • 19. Meng L, Cannesson M, Alexander BS, Yu Z, Kain ZN, Cerussi AE, et al. Effect of phenylephrine and ephedrine bolus treatment on cerebral oxygenation in anaesthetized patients. Br J Anaesth 2011;107:209−17.
  • 20. da Costa CS, Greisen G, Austin T. Is near-infrared spectroscopy clinically useful in the preterm infant?. Arch Dis Child Fetal Neonatal Ed 2015;100:F558–61.
  • 21. Naulaers G, Meyns B, Miserez M, Leunens V, Van Huffel S, Casaer P, et al. Use of tissue oxygenation index and fractional tissue oxygen extraction as non-invasive parameters for cerebral oxygenation. A validation study in piglets. Neonatology 2007;92:120−6.
  • 22. Edmonds HL Jr, Ganzel BL, Austin EH 3rd. Cerebral oximetry for cardiac and vascular surgery. Semin Cardiothorac Vasc Anesth 2004;8:147– 66.
  • 23. Fellahi JL, Butin G, Fischer MO, Zamparini G, Gérard JL, Hanouz JL. Dynamic evaluation of near-infrared peripheral oximetry in healthy volunteers: a comparison between INVOS and EQUANOX. J Crit Care 2013;28:881.e1–881.e8816.
  • 24. Westgarth-Taylor C, de Lijster L, van Bogerijen G, Millar AJ, Karpelowsky J. A prospective assessment of renal oxygenation in children undergoing laparoscopy using near-infrared spectroscopy. Surg Endosc 2013;27:3696–704.
  • 25. Gillam-Krakauer M, Cochran CM, Slaughter JC, Polavarapu S, McElroy SJ, Hernanz-Schulman M, et al. Correlation of abdominal rSO2 with superior mesenteric artery velocities in preterm infants. J Perinatol 2013;33:609−12.
  • 26. Nahum E, Skippen PW, Gagnon RE, Macnab AJ, Skarsgard ED. Correlation of near-infrared spectroscopy with perfusion parameters at the hepatic and systemic levels in an endotoxemic shock model. Med Sci Monit 2006;12:BR313–7.
  • 27. Said MM, Niforatos N, Rais-Bahrami K. Validation of near infrared spectroscopy to measure abdominal somatic tissue oxygen saturation in neonates. J Neonatal Perinatal Med 2013;6:23–30.
  • 28. Varela JE, Cohn SM, Giannotti GD, Dolich MO, Ramon H, Wiseberg JA, et al. Near-infrared spectroscopy reflects changes in mesenteric and systemic perfusion during abdominal compartment syndrome. Surgery 2001;129:363−70.
  • 29. Li J, Van Arsdell GS, Zhang G, Cai S, Humpl T, Caldarone CA, et al. Assessment of the relationship between cerebral and splanchnic oxygen saturations measured by near-infrared spectroscopy and direct measurements of systemic haemodynamic variables and oxygen transport after the Norwood procedure. Heart 2006;92:1678−85.
  • 30. Toraman F, Ustalar Özgen S, Arıtürk C, Sayın J, Erkek E, Güçlü P, et al. Is It Effıcient to Use NIRS to Calculate Hepatic and Renal Oxygen Saturation During Extracorporeal Circulation?. ACU Sağlık Bil Derg 2012;3:164−9.
APA ZİYAN M, Kalkan A, Bilir O, ERSUNAN G, Özel D, UZUN Ö, KORKU S (2020). A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. , 178 - 185. 10.14744/tjtes.2019.72627
Chicago ZİYAN Murat,Kalkan Asım,Bilir Ozlem,ERSUNAN Gökhan,Özel Deniz,UZUN Özlem,KORKU Semih A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. (2020): 178 - 185. 10.14744/tjtes.2019.72627
MLA ZİYAN Murat,Kalkan Asım,Bilir Ozlem,ERSUNAN Gökhan,Özel Deniz,UZUN Özlem,KORKU Semih A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. , 2020, ss.178 - 185. 10.14744/tjtes.2019.72627
AMA ZİYAN M,Kalkan A,Bilir O,ERSUNAN G,Özel D,UZUN Ö,KORKU S A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. . 2020; 178 - 185. 10.14744/tjtes.2019.72627
Vancouver ZİYAN M,Kalkan A,Bilir O,ERSUNAN G,Özel D,UZUN Ö,KORKU S A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. . 2020; 178 - 185. 10.14744/tjtes.2019.72627
IEEE ZİYAN M,Kalkan A,Bilir O,ERSUNAN G,Özel D,UZUN Ö,KORKU S "A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy." , ss.178 - 185, 2020. 10.14744/tjtes.2019.72627
ISNAD ZİYAN, Murat vd. "A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy". (2020), 178-185. https://doi.org/10.14744/tjtes.2019.72627
APA ZİYAN M, Kalkan A, Bilir O, ERSUNAN G, Özel D, UZUN Ö, KORKU S (2020). A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. Ulusal Travma ve Acil Cerrahi Dergisi, 26(2), 178 - 185. 10.14744/tjtes.2019.72627
Chicago ZİYAN Murat,Kalkan Asım,Bilir Ozlem,ERSUNAN Gökhan,Özel Deniz,UZUN Özlem,KORKU Semih A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. Ulusal Travma ve Acil Cerrahi Dergisi 26, no.2 (2020): 178 - 185. 10.14744/tjtes.2019.72627
MLA ZİYAN Murat,Kalkan Asım,Bilir Ozlem,ERSUNAN Gökhan,Özel Deniz,UZUN Özlem,KORKU Semih A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. Ulusal Travma ve Acil Cerrahi Dergisi, vol.26, no.2, 2020, ss.178 - 185. 10.14744/tjtes.2019.72627
AMA ZİYAN M,Kalkan A,Bilir O,ERSUNAN G,Özel D,UZUN Ö,KORKU S A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. Ulusal Travma ve Acil Cerrahi Dergisi. 2020; 26(2): 178 - 185. 10.14744/tjtes.2019.72627
Vancouver ZİYAN M,Kalkan A,Bilir O,ERSUNAN G,Özel D,UZUN Ö,KORKU S A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy. Ulusal Travma ve Acil Cerrahi Dergisi. 2020; 26(2): 178 - 185. 10.14744/tjtes.2019.72627
IEEE ZİYAN M,Kalkan A,Bilir O,ERSUNAN G,Özel D,UZUN Ö,KORKU S "A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy." Ulusal Travma ve Acil Cerrahi Dergisi, 26, ss.178 - 185, 2020. 10.14744/tjtes.2019.72627
ISNAD ZİYAN, Murat vd. "A new technique in the evaluation of strangulated and incarcerated hernias: Near-infrared spectroscopy". Ulusal Travma ve Acil Cerrahi Dergisi 26/2 (2020), 178-185. https://doi.org/10.14744/tjtes.2019.72627