Yıl: 2020 Cilt: 26 Sayı: 2 Sayfa Aralığı: 280 - 286 Metin Dili: İngilizce DOI: 10.14744/tjtes.2020.94490 İndeks Tarihi: 05-10-2020

Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study

Öz:
ABSTRACTBACKGROUND: Intramedullary nailing (IMN) technique is the gold standard for the treatment of closed fractures of the lower extremity long bones. For orthopedic surgeons, one of the most important problems in IMN procedures is the fixation of distal locking screws (DLS). Accurate and rapid placement of DLSs with minimal radiation exposure is crucial. In this study, we aimed to compare the results of two different distal locking methods concerning surgery duration and radiation exposure in patients who underwent osteosynthesis of tibia fractures with IMN.METHODS: In this prospective study, the results of 56 patients who met the inclusion and exclusion criteria from 72 patients were evaluated. Patients were divided into two groups according to the distal screwing method. Group 1 (n=29) comprised patients who used free-hand technique (FHT) for distal locking, while Group 2 (n=27) consisted of patients who used electromagnetic guidancesystem (EMGS) for distal locking. Demographic and medical data of the patients, duration of surgery time, amount of bleeding, total fluoroscopy counts, the time elapsed for distal locking, the measure of radiation exposure, number of attempts for distal screw locking, incorrect screw placements, complications and follow-up time were recorded. The groups were compared concerning demographicdata and clinical results.RESULTS: There was no statistically significant difference between the groups about gender and side (p=0.928 and p=0.432, respectively). The mean age in Group-1 was higher than that of Group-2, and the difference was statistically significant (p=0.012). However, there was no statistically significant difference in length of hospital stay in Group-1 (p=0.140). On the other hand, in Group-2, thenumber of distal shots, fluoroscopy duration, effective radiation dose and operation duration were lower compared to Group-1, although this difference was not statistically significant (p=0.057, 0.073, 0.058 and 0.056, respectively). Failure was encountered in distal locking during the first attempt in three cases in Group-1 and in two cases in Group-2. Aseptic nonunion was observed in one patientin both groups.CONCLUSION: Both the FHT distal screwing technique and the EMGS distal screwing technique are highly effective methods for distal locking. The duration of operation, the duration of the fluoroscopy and radiation exposure were similar. FHT can be preferred for distal locking in conventional intramedullary nail applications, as it is effective, easy and inexpensive.
Anahtar Kelime:

Tibia kırıklarının intramedüller çivilemesinde, distal kilitleme için elektromanyetik yönlendirme sistemi, serbest el tekniğinden üstün müdür? İleriye yönelik karşılaştırmalı bir çalışma

Öz:
AMAÇ: İntramedüller çivileme (İMÇ) tekniği, alt ekstremite uzun kemiklerinin kapalı kırıklarının tedavisinde altın standarttır. Ortopedik cerrahlar için İMÇ prosedürlerindeki en önemli sorunlardan biri distal kilitleme vidalarının (DKV) yerleştirilmesidir. DKV’ların en az radyasyona maruz kalma ile doğru ve hızlı bir şekilde yerleştirilmesi çok önemlidir. Bu çalışmada, tibia kırıklarında İMÇ ile osteosentez uygulanan hastalarda ameliyat süresi ve radyasyon maruziyeti açısından iki farklı distal kilitleme yönteminin sonuçlarını karşılaştırmayı amaçladık.GEREÇ VE YÖNTEM: İleriye yönelik yapılan bu çalışmada toplamda 72 hastadan dahil etme ve dışlama kriterlerini karşılayan 56 olgunun sonuçları değerlendirildi. Hastalar distal vidalama yöntemine göre iki gruba ayrıldı. Grup-1 (n=29) distal kilitleme için serbest el tekniği (SET) kullanılan hastaları, Grup-2 (n=27) distal kilitleme için elektromanyetik yönlendirme sistemi (EMYS) kullanılan hastaları içeriyordu. Hastaların demografik ve tıbbi bilgileri, ameliyat süreleri, kanama miktarları, toplam floroskopi süreleri, distal kilitleme için geçen süreler, maruz kalınan radyasyon dozu ölçümleri, distal vida kilitleme için teşebbüs sayıları, hatalı vida yerleşimleri, komplikasyonlar ve takip süreleri kaydedildi. Gruplar demografik veriler ve klinik sonuçlar açısından karşılaştırıldı.BULGULAR: Gruplar arasında cinsiyet ve taraf açısından istatistiksel olarak anlamlı fark yoktu (sırasıyla, p=0.928 ve p=0.432). Grup 1’deki yaş ortalaması Grup-2’den daha yüksekti ve fark istatistiksel olarak anlamlı idi (p=0.012). Ancak, Grup-1’de hastanede kalış süresi açısından istatistiksel olarak anlamlı bir fark yoktu (p=0.140). Diğer taraftan Grup-2’de distal atım sayısı, floroskopi süresi, etkili radyasyon dozu ve operasyon süresi Grup-1’e göre daha düşüktü, ancak bu fark istatistiksel olarak anlamlı değildi (sırasıyla, p=0.057, 0.073, 0.058 ve 0.056). Grup-1’deki üç olguda ve Grup-2’deki iki olguda ilk denemede distal kilitlemede başarısızlıkla karşılaşıldı. Her iki grupta bir hastada aseptik kaynamama gözlendi.TARTIŞMA: Hem SET hem de EMYS distal vidalama tekniği, distal kilitleme için oldukça etkili yöntemlerdir. Ameliyat süresi, floroskopi süresi ve radyasyona maruz kalma benzerdir. Geleneksel İMÇ uygulamalarındaki distal kilitlemelerde, etkili, kolay ve ucuz olduğu için SET tercih edilebilir.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Zhu Y, Chang H, Yu Y, Chen W, Liu S, Zhang Y. Meta-analysis suggests that the electromagnetic technique is better than the free-hand method for the distal locking during intramedullary nailing procedures. Int Orthop 2017;41:1041–8.
  • 2. Aldemir C, Doğan A, İnci F, Sertkaya Ö, Duygun F. Distal locking techniques without fluoroscopy in intramedullar nailing. Eklem Hastalik Cerrahisi 2014;25:64–9.
  • 3. Whatling GM, Nokes LD. Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury 2006;37:109–19.
  • 4. Konya MN, Kaya ÖA. Can radiation exposure be reduced in the treatment of femur fractures with the Intrameduller nail? Acta Med Alanya 2017;1:22−3.
  • 5. Uruc V, Ozden R, Dogramacı Y, Kalacı A, Dikmen B, Yıldız OS, et al. The comparison of freehand fluoroscopic guidance and electromagnetic navigation for distal locking of intramedullary implants. Injury 2013;44:863−6.
  • 6. Stathopoulos I, Karampinas P, Evangelopoulos DS, Lampropoulou-Adamidou K, Vlamis J. Radiation-free distal locking of intramedullary nails: evaluation of a new electromagnetic computer-assisted guidance system. Injury 2013;44:872–5.
  • 7. Abdlslam KM, Bonnaire F. Experimental model for a new distal locking aiming device for solid intramedullary tibia nails. Injury 2003;34:363–6.
  • 8. Suhm N, Messmer P, Zuna I, Jacob LA, Regazzoni P. Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study. Injury 2004;35:567–74.
  • 9. Malek S, Phillips R, Mohsen A, Viant W, Bielby M, Sherman K. Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: a valid and reliable navigation system. Int J Med Robot 2005;1:34–44.
  • 10. Zirkle LG Jr, Shearer D. SIGN technique for retrograde and antegrade approaches to femur. Tech Orthop 2009;24:247−52.
  • 11. Ricci WM, Russell TA, Kahler DM, Terrill-Grisoni L, Culley P. A comparison of optical and electromagnetic computer-assisted navigation systems for fluoroscopic targeting. J Orthop Trauma 2008;22:190–4.
  • 12. Han B, Shi Z, Fu Y, Ye Y, Jing J, Li J. Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of femoral intramedullary nails. Medicine (Baltimore) 2017;96(:e7450.
  • 13. Moreschini O, Petrucci V, Cannata R. Insertion of distal locking screws of tibial intramedullary nails: a comparison between the free-hand technique and the SURESHOT™ Distal Targeting System. Injury 2014;45:405–7.
  • 14. Soni RK, Mehta SM, Awasthi B, Singh JL, Kumar A, Thakur L, et al. Radiation-free Insertion of Distal Interlocking Screw in Tibial and Femur Nailing: A Simple Technique. J Surg Tech Case Rep 2012;4:15−8.
  • 15. Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF. Fracture and Dislocation Classification Compendium-2018. J Orthop Trauma 2018;32 Suppl 1:S1–S170.
  • 16. Krettek C, Miclau T, Grün O, Schandelmaier P, Tscherne H. Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note. Injury 1998;29 Suppl 3:C29–C39.
  • 17. Müller MC, Welle K, Strauss A, Naehle PC, Pennekamp PH, Weber O, et al. Real-time dosimetry reduces radiation exposure of orthopaedic surgeons. Orthop Traumatol Surg Res 2014;100:947−51.
  • 18. Kirousis G, Delis H, Megas P, Lambiris E, Panayiotakis G. Dosimetry during intramedullary nailing of the tibia. Acta Orthop 2009;80:568–72.
  • 19. Ehlinger M, Dillman G, Czekaj J, Adam P, Taglang G, Brinkert D, et al. Distal targeting device for long Gamma nail(®). Monocentric observational study. Orthop Traumatol Surg Res 2013;99:799−804.
  • 20. Lee YS, Lee HK, Cho JH, Kim HG. Analysis of radiation risk to patients from intra-operative use of the mobile X-ray system (C-arm). J Res Med Sci 2015;20:7–12.
  • 21. Tyropoulos S, Garnavos C. A new distal targeting device for closed interlocking nailing. Injury 2001;32:732–5.
  • 22. Levin PE, Schoen RW Jr, Browner BD. Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J Bone Joint Surg Am 1987;69:761–6.
  • 23. Hoffmann M, Schröder M, Lehmann W, Kammal M, Rueger JM, Herrman Ruecker A. Next generation distal locking for intramedullary nails using an electromagnetic X-ray-radiation-free real-time navigation system. J Trauma Acute Care Surg 2012;73:243–8.
  • 24. Langfitt MK, Halvorson JJ, Scott AT, Smith BP, Russell GB, Jinnah RH, et al. Distal locking using an electromagnetic field-guided computer-based real-time system for orthopaedic trauma patients. J Orthop Trauma 2013;27:367−72.
  • 25. Dursun M, Kalkan T, Aytekin MN, Celik I, Uğurlu M. Does the magnetic-guided intramedullary nailing technique shorten operation time and radiation exposure?. Eur J Orthop Surg Traumatol 2014;24:1005–11.
  • 26. Muzaffar TS, Imran Y, Iskandar MA, Zakaria A. Radiation exposure to the surgeon during femoral interlocking nailing under fluoroscopic imaging. Med J Malaysia 2005;60 Suppl C:26–9.
  • 27. Blattert TR, Fill UA, Kunz E, Panzer W, Weckbach A, Regulla DF. Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study. Arch Orthop Trauma Surg 2004;124:659–64.
  • 28. Fuchs M, Schmid A, Eiteljörge T, Modler M, Stürmer KM. Exposure of the surgeon to radiation during surgery. Int Orthop 1998;22:153–6.
  • 29. Coetzee JC, van der Merwe EJ. Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures. S Afr Med J 1992;81:312–4.
  • 30. Kim KP, Miller DL, Berrington de Gonzalez A, Balter S, Kleinerman RA, et al. Occupational radiation doses to operators performing fluoroscopically-guided procedures. Health Phys 2012;103:80−99.
APA Aslan A, KONYA M, Gülcü A, SARGIN A (2020). Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. , 280 - 286. 10.14744/tjtes.2020.94490
Chicago Aslan Ahmet,KONYA Mehmet Nuri,Gülcü Anıl,SARGIN Assoc.Prof. Serdar Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. (2020): 280 - 286. 10.14744/tjtes.2020.94490
MLA Aslan Ahmet,KONYA Mehmet Nuri,Gülcü Anıl,SARGIN Assoc.Prof. Serdar Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. , 2020, ss.280 - 286. 10.14744/tjtes.2020.94490
AMA Aslan A,KONYA M,Gülcü A,SARGIN A Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. . 2020; 280 - 286. 10.14744/tjtes.2020.94490
Vancouver Aslan A,KONYA M,Gülcü A,SARGIN A Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. . 2020; 280 - 286. 10.14744/tjtes.2020.94490
IEEE Aslan A,KONYA M,Gülcü A,SARGIN A "Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study." , ss.280 - 286, 2020. 10.14744/tjtes.2020.94490
ISNAD Aslan, Ahmet vd. "Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study". (2020), 280-286. https://doi.org/10.14744/tjtes.2020.94490
APA Aslan A, KONYA M, Gülcü A, SARGIN A (2020). Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. Ulusal Travma ve Acil Cerrahi Dergisi, 26(2), 280 - 286. 10.14744/tjtes.2020.94490
Chicago Aslan Ahmet,KONYA Mehmet Nuri,Gülcü Anıl,SARGIN Assoc.Prof. Serdar Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. Ulusal Travma ve Acil Cerrahi Dergisi 26, no.2 (2020): 280 - 286. 10.14744/tjtes.2020.94490
MLA Aslan Ahmet,KONYA Mehmet Nuri,Gülcü Anıl,SARGIN Assoc.Prof. Serdar Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. Ulusal Travma ve Acil Cerrahi Dergisi, vol.26, no.2, 2020, ss.280 - 286. 10.14744/tjtes.2020.94490
AMA Aslan A,KONYA M,Gülcü A,SARGIN A Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. Ulusal Travma ve Acil Cerrahi Dergisi. 2020; 26(2): 280 - 286. 10.14744/tjtes.2020.94490
Vancouver Aslan A,KONYA M,Gülcü A,SARGIN A Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study. Ulusal Travma ve Acil Cerrahi Dergisi. 2020; 26(2): 280 - 286. 10.14744/tjtes.2020.94490
IEEE Aslan A,KONYA M,Gülcü A,SARGIN A "Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study." Ulusal Travma ve Acil Cerrahi Dergisi, 26, ss.280 - 286, 2020. 10.14744/tjtes.2020.94490
ISNAD Aslan, Ahmet vd. "Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study". Ulusal Travma ve Acil Cerrahi Dergisi 26/2 (2020), 280-286. https://doi.org/10.14744/tjtes.2020.94490