Yıl: 2018 Cilt: 3 Sayı: 1 Sayfa Aralığı: 1 - 5 Metin Dili: İngilizce DOI: 10.26833/ijeg.333686 İndeks Tarihi: 17-11-2020

DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY

Öz:
Photogrammetry has been used for medical diagnostic and treatment. Mostly used medicalphotogrammetric techniques are Ultrasound, Computed Tomography (CT) and Magnetic Resonance Imaging (MRI)images. CT and MRI are the most effective method for the early detection of foot and ankle anomaly. Researchers havebeen developing various methods to detect anomaly. Many image segmentation techniques are available in the literature.Computer Aided Diagnosing (CAD) system has been proposed in this study for detection of foot bone anomaly by theanalysis of CT images. In this study, a segmentation based on edge detection method is proposed for the classification ofanomaly in foot CT images. Edge detection algorithms are the most commonly used techniques in image processing foredge detection. Canny edge detector is evaluated in this study.In this study, “.dicom” medical image standard format and ten male patient's foot CT images (245 images and 50 testdata) are used. The used parameters are detector collimation of 64 mm, scanning thickness of 1-5 mm, and pixel sizes of512x512 in radiometric resolution of 16 bits’ gray levels.The proposed method consists of five major steps: (i) calculating the horizontal & vertical gradient, (ii) determininggradient magnitude and gradient direction, (iii) applying non-maximal suppression, (iv) computing high and lowthresholds, (v) hysteresis thresholding are applied to the multi-detector computed tomography to detect the bone anomaly.In this study, automatic edge-based digital image processing techniques are applied to detect of foot bone anomaly.The proposed canny segmentation method enables users segment anomaly in MDCT of foot very quickly and efficiently.The results demonstrate that the proposed segmentation method is effective for segmenting anomaly. The proposedmethod obtains satisfactory performances in terms of accuracy and F-measure the area under Receiver OperatingCharacteristic curve (ROC curve (AUC)). The proposed segmentation method achieves an accuracy of 0.86 and Fmeasureof 0.92, respectively.The purpose of our study is to detect the anomaly of the foot and it was the simplest and less time consuming process.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • Bakotic, B. and Huvos, A.G., 2001. Tumors of the Bones of the Feet: The Clinicopathologic Features of 150 Cases, Journal of Foot & Ankle Surgery, 40(5), pp. 277 -286.
  • Biswas, R. and Sil, J., 2012. An Improved Canny Edge Detection Algorithm Based on Type-2 Fuzzy Sets, Procedia Technology, 4, pp. 820 – 824.
  • Canny, J.F., 1983. Finding Edges and Lines in Images, Technical Report AI-TR-720, MIT, Artificial Intelligence Laboratory, Cambridge, MA.
  • Canny, J.F., 1986. A Computational Approach to Edge Detection, IEEE Transactions on Pattern Analysis and Machine Intelligence, 8(6), pp. 679-698.
  • Catal Reis, H., Bayram, B. and Seker, D.Z., 2016. Bone Tumor Segmentation by Gradient Operators from CT Images, Selcuk International Scientific Conference on Applied Sciences (The Selçuk ISCAS 2016), 27-30 September, Antalya, Turkey.
  • Doi, K., 2007. Computer-Aided Diagnosis in Medical Imaging: Historical Review, Current Status and Future Potential, Comput Med Imaging Graph., 31(4-5), pp. 198–211.
  • Foo, L.F. and Raby, N., 2005. Tumors and Tumor-like Lesions in the Foot and Ankle, Clinical Radiology, 60, pp. 308–332.
  • Giger, M.L., Huo, Z., Kupinski, M.A., Vyborny, C.J., 2000. Computer-Aided Diagnosis in Mammography. In: Fitzpatrick JM, Sonka M, editors. The Handbook of Medical Imaging, volume 2 Medical Imaging Processing and Analysis, SPIE, pp. 915–1004.
  • Gonzalez, R.C. and Woods, R.E., 2007. Digital Image Processing”, 2nd ed., Beijing: Publishing House of Electronics Industry.
  • Hasbek Z., Salk I.., Yucel B., Akgul Babacan, N., 2013. Which Imaging Method to Choose for Detection of Bone Metastases? Bone Scintigraphy, CT, 18F-FDG PET/CT or MR? Bozok Med J, 3(3), pp. 44-50.
  • Jepson, A.D. and Fleet, D.J., Edge Detection, 2009, http://www.cs.toronto.edu/~jepson/csc2503/edgeDetecti on.pdf, 1 Nov 2015.
  • Kabade, A.L. and Sangam, V.G., 2016. Canny Edge Detection Algorithm, International Journal of Advanced Research in Electronics and Communication Engineering (IJARECE), 5(5), pp. 1292-1296.
  • Kizilkaya, A., 2008. Department of Electrical Engineering, Lecture Note, Pamukkale University, Denizli- Turkey.
  • Lodwick, G.S., Haun, C.L., Smith, W.E., Keller, R.F. and Robertson, E.D., 1963. Computer Diagnosis of Primary Bone Tumors. A prelim. Report, 80, pp. 273-5. Maini, R. and Aggarwa, H., 2009. Study and Comparison of Various Image Edge Detection Techniques, International Journal of Image Processing (IJIP), 3(1), pp. 1-11.
  • Mascard, E., Gaspar, N., Brugières, L., Glorion, C., Pannier, S. and Gomez-Brouchet, A., 2017. Malignant Tumours of the Foot and Ankle, EFORT Open Rev., 2(5), pp. 261–271.
  • Obuchowski, N.A., 2005. ROC Analysis, Fundamentals of Clinical Research for Radiologists, American College of Radiology (ACR), 184, pp. 364-372.
  • Ozer, D., Er, T., Aycan O.E., Oke, R., Coskun, M. and Kabukcuoglu, Y.S., 2014. May Bone Cement Be Used To Treat Benign Aggressive Bone Tumors of the Feet with Confidence? The Foot, 24, pp. 1–5.
  • Rice, B.M., Todd, N.W., Jensen, R., Rush, S.M. and William Rogers, W., 2014. Metastatic Calcaneal Lesion Associated with Uterine Carcinosarcoma, The Journal of Foot & Ankle Surgery, 53, pp. 364–368.
  • Rong, W., Li, Z., Zhang, W. and Sun, L., 2014. An Improved Canny Edge Detection Algorithm, Mechatronics and Automation (ICMA), IEEE International Conference, 3-6 Aug. 2014, Tianjin, China.
  • Toriwaki, J., Suenaga, Y., Negoro, T, et al., 1973. Pattern Recognition of Chest X-Ray Images, Computer Graphics and Image Processing, 2, pp. 252–271.
  • Yogamangalam, R. and Karthikeyan, B., 2013. Segmentation Techniques Comparison in Image Processing, International Journal of Engineering and Technology (IJET), 5(1) (Feb-Mar).
APA ÇATAL REİS H (2018). DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. , 1 - 5. 10.26833/ijeg.333686
Chicago ÇATAL REİS Hatice DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. (2018): 1 - 5. 10.26833/ijeg.333686
MLA ÇATAL REİS Hatice DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. , 2018, ss.1 - 5. 10.26833/ijeg.333686
AMA ÇATAL REİS H DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. . 2018; 1 - 5. 10.26833/ijeg.333686
Vancouver ÇATAL REİS H DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. . 2018; 1 - 5. 10.26833/ijeg.333686
IEEE ÇATAL REİS H "DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY." , ss.1 - 5, 2018. 10.26833/ijeg.333686
ISNAD ÇATAL REİS, Hatice. "DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY". (2018), 1-5. https://doi.org/10.26833/ijeg.333686
APA ÇATAL REİS H (2018). DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. International Journal of Engineering and Geosciences, 3(1), 1 - 5. 10.26833/ijeg.333686
Chicago ÇATAL REİS Hatice DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. International Journal of Engineering and Geosciences 3, no.1 (2018): 1 - 5. 10.26833/ijeg.333686
MLA ÇATAL REİS Hatice DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. International Journal of Engineering and Geosciences, vol.3, no.1, 2018, ss.1 - 5. 10.26833/ijeg.333686
AMA ÇATAL REİS H DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. International Journal of Engineering and Geosciences. 2018; 3(1): 1 - 5. 10.26833/ijeg.333686
Vancouver ÇATAL REİS H DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY. International Journal of Engineering and Geosciences. 2018; 3(1): 1 - 5. 10.26833/ijeg.333686
IEEE ÇATAL REİS H "DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY." International Journal of Engineering and Geosciences, 3, ss.1 - 5, 2018. 10.26833/ijeg.333686
ISNAD ÇATAL REİS, Hatice. "DETECTION OF FOOT BONE ANOMALY USING MEDICAL PHOTOGRAMMETRY". International Journal of Engineering and Geosciences 3/1 (2018), 1-5. https://doi.org/10.26833/ijeg.333686