Yıl: 2020 Cilt: 6 Sayı: 2 Sayfa Aralığı: 52 - 60 Metin Dili: İngilizce DOI: 10.20528/cjsmec.2020.02.001 İndeks Tarihi: 02-11-2020

A study on seismic isolation of building used LRB

Öz:
Base isolation system with lead rubber bearing (LRB) is commonly used to preventstructure against to damage of earthquake. Design of LRB system is detailed in thisstudy. The isolated building with LRB design according to Uniform Building Code(UBC-97) and fixed building were examined. The six-storey building with LRB andfixed building were modelled in SAP2000 with the same dynamic loads. The relativefloor displacement and internal forces of the seismic isolated and fixed building arecompared. In addition, transverse and longitudinal reinforcement of any axis of seismic isolated and fixed building are compared. Analyse results showed that effectiveness of using seismic isolation system on building. The weight of longitudinal andtransverse reinforcement of isolated building is smaller than fixed building about36%, 40% respectively.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • Abadi MMT, Adhami B (2016). Improving the seismic behavior of symmetrical steel structures under near-field earthquake using a base isolation method lead rubber bearing isolator. Modern Applied Science, 10(7), 10-21.
  • Atmaca B, Ateş Ş (2017). Determination of bearing type effect on elastomeric bearing selection with SREI-CAD. Advances in Computational Design, 2(1), 43-56.
  • Billah AM, Todorov B (2019). Effects of subfreezing temperature on the seismic response of lead rubber bearing isolated bridge. Soil Dynamics and Earthquake Engineering, 126, 105814.
  • Habieb AB, Valente M, Milani G (2019). Base seismic isolation of a historical masonry church using fiber reinforced elastomeric isolators. Soil Dynamics and Earthquake Engineering, 120, 127-145.
  • Kumar P, Petwala S (2019). Seismic performance of secondary systems housed in isolated and non-isolated building. Earthquake and Structures, 16(4), 401-413.
  • Nakhostin H, Poursha FM (2017). Applicability of the N2, extended N2 and modal pushover analysis methods for the seismic evaluation of base-isolated building frames with lead rubber bearings (LRBs). Soil Dynamics and Earthquake Engineering, 98, 84-100.
  • Reddy MR, Srujana N, Lingeshwaran N (2017). Effect of base isolation in multistoried reinforced concrete building. International Journal of Civil Engineering and Technology, 8(3), 878-887.
  • Shoaei P, Mahsuli M (2019). Reliability-based design of steel moment frame structures isolated by lead-rubber bearing systems. Structures, 20, 765-778.
  • Su L, Ahmadi G, Tadjbakhsh IG (1989). Comparative Study of base isolation systems. Journal of Engineering Mechanics, 115(9), 1976- 1992.
  • Tanwer MT, Kazi TA, Desai M (2018). A study on different types of base isolation system over fixed based, Smart Innovation, Systems and Technologies, 106, 725-734.
  • Tavakoli HR, Naghavia F, Goltabar AR (2015). Effect of base isolation systems on increasing the resistance of structures subjected to progressive collapse. Earthquakes and Structures, 9(3), 639-656.
  • UBC-97 (1997). Uniform Building Code. American Structural Engineering Design Provisions, USA.
  • Wu Y, Wang H, Ben S, Rui-jun Z, Lin A (2018). The compression-shear properties of small-size seismic isolation rubber bearings for bridges. Structural Monitoring and Maintenance, 5(1), 39-50.
  • Zhi-hua L, Zhi-j iang H, Lei W (2016). Experimental study of seismic isolation performance of PC continuous beam bridge using leadrubber bearings. Bridge Construction, 46(5), 18-23.
APA YURDAKUL M, YILDIZ B (2020). A study on seismic isolation of building used LRB. , 52 - 60. 10.20528/cjsmec.2020.02.001
Chicago YURDAKUL MUHAMMET,YILDIZ Burak A study on seismic isolation of building used LRB. (2020): 52 - 60. 10.20528/cjsmec.2020.02.001
MLA YURDAKUL MUHAMMET,YILDIZ Burak A study on seismic isolation of building used LRB. , 2020, ss.52 - 60. 10.20528/cjsmec.2020.02.001
AMA YURDAKUL M,YILDIZ B A study on seismic isolation of building used LRB. . 2020; 52 - 60. 10.20528/cjsmec.2020.02.001
Vancouver YURDAKUL M,YILDIZ B A study on seismic isolation of building used LRB. . 2020; 52 - 60. 10.20528/cjsmec.2020.02.001
IEEE YURDAKUL M,YILDIZ B "A study on seismic isolation of building used LRB." , ss.52 - 60, 2020. 10.20528/cjsmec.2020.02.001
ISNAD YURDAKUL, MUHAMMET - YILDIZ, Burak. "A study on seismic isolation of building used LRB". (2020), 52-60. https://doi.org/10.20528/cjsmec.2020.02.001
APA YURDAKUL M, YILDIZ B (2020). A study on seismic isolation of building used LRB. Challenge Journal of Structural Mechanics, 6(2), 52 - 60. 10.20528/cjsmec.2020.02.001
Chicago YURDAKUL MUHAMMET,YILDIZ Burak A study on seismic isolation of building used LRB. Challenge Journal of Structural Mechanics 6, no.2 (2020): 52 - 60. 10.20528/cjsmec.2020.02.001
MLA YURDAKUL MUHAMMET,YILDIZ Burak A study on seismic isolation of building used LRB. Challenge Journal of Structural Mechanics, vol.6, no.2, 2020, ss.52 - 60. 10.20528/cjsmec.2020.02.001
AMA YURDAKUL M,YILDIZ B A study on seismic isolation of building used LRB. Challenge Journal of Structural Mechanics. 2020; 6(2): 52 - 60. 10.20528/cjsmec.2020.02.001
Vancouver YURDAKUL M,YILDIZ B A study on seismic isolation of building used LRB. Challenge Journal of Structural Mechanics. 2020; 6(2): 52 - 60. 10.20528/cjsmec.2020.02.001
IEEE YURDAKUL M,YILDIZ B "A study on seismic isolation of building used LRB." Challenge Journal of Structural Mechanics, 6, ss.52 - 60, 2020. 10.20528/cjsmec.2020.02.001
ISNAD YURDAKUL, MUHAMMET - YILDIZ, Burak. "A study on seismic isolation of building used LRB". Challenge Journal of Structural Mechanics 6/2 (2020), 52-60. https://doi.org/10.20528/cjsmec.2020.02.001