Yıl: 2020 Cilt: 26 Sayı: 1 Sayfa Aralığı: 10 - 16 Metin Dili: İngilizce DOI: 10.5222/GKDAD.2020.65983 İndeks Tarihi: 07-12-2020

Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement

Öz:
Objective: In this study, we aimed to compare fiberoptic bronchoscope (FOB) andDisposcope® endoscope (DE),which is one of the optical imaging methods used in Cohenflexitip bronchial blocker placement.Methods: In this study, a total of 40 patients in whom a bronchial blocker was inserted forone-lung ventilation were randomly assigned into two groups as FOB (n=20) and DE (n=20).Data including demographic and clinical characteristics of the patients, Cormack-Lehanegrade, duration and ease of bronchial blocker placement were recorded.Results: The mean bronchial blocker insertion time in the DE group (196±32 sec) wasshorter than the mean BB insertion time in the FOB group (244±21 sec) with a statisticallysignificant intergroup difference (p<0.05). In both FOB and DE groups, it was found thatplacement of DE, and BB into the right main bronchus was easier when compared with theleft main bronchus (p<0.05).Conclusion: Disposcope® endoscope-guided Cohen flexitip bronchial blocker placement is asuitable option for one- lung ventilation in thoracic surgery with its easy placement withina shorter time.
Anahtar Kelime:

Cohen Endobronşiyal Bloker Yerleştirmesinde Fiberoptik Bronkoskop ve Disposcope Endoskopun Karşılaştırması

Öz:
Amaç: Bu çalışmada, Cohen fleksitip bronşiyal bloker yerleştirilmesinde kullanılan optik görüntüleme yöntemlerinden, fiberoptik bronkoskop (FOB) ve Disposcope® endoskopu (DE) karşılaştırmayı amaçladık. Yöntem: Bu çalışmada, tek akciğer ventilasyonu için bronşiyal bloker yerleştirilen 40 hasta randomize olarak FOB grubu (n=20) ve DE grubu (n=20) olmak üzere 2 gruba ayrıldı. Hastaların demografik ve klinik özellikleri, Cormack-Lehane sınıflaması, bronşiyal blokerin yerleştirme süresi ve kolaylığı kaydedildi. Bulgular: DE grubunun ortalama bronşiyal bloker yerleştirilme süresinin (196±32 sn); FOB grubunun bronşiyal bloker yerleştirilme süresine göre (244±21 sn) daha kısa olduğu belirlendi ve istatistiksel olarak anlamlı bulundu (p<0.05). Hem FOB hem de DE gruplarında; sağ ana bronşa yerleşimin, sol ana bronştan daha kolay olduğu bulundu (p<0.05). Sonuç: Torasik cerrahi pratiğinde Disposcope® endoskop kılavuzluğunda Cohen flexitip bronşiyal bloker yerleştirilmesi, kısa ve kolay yerleşimi ile, tek akciğer ventilasyonu için uygun bir seçenektir.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Campos JH. Progress in lung separation. Thorac Surg Clin. 2005;15:71-83. https://doi.org/10.1016/j.thorsurg.2004.09.003
  • 2. Campos JH. Lung isolation techniques for patients with difficult airway. Curr Opin Anaesthesiol. 2010;23:12-7. https://doi.org/10.1097/ACO.0b013e328331e8a7
  • 3. Disposcope. Product information. Available at: http:// www.disposcope.com/news.html. Accessed April 10, 2014.
  • 4. Dumans-Nizard V, Liu N, Laloe PA, et al. A comparison of the deflecting-tip bronchial blocker with a wireguided or left-sided double-lumen tube. J Cardiothorac Vasc Anesth. 2009;23:501-5. https://doi.org/10.1053/j.jvca.2009.02.002
  • 5. Kus A, Hosten T, Gurkan Y, Akgul AG, Solak M, Toker K. A comparison of the EZ-blocker with a Cohen flex-tip blocker for one-lung ventilation. Journal of Cardiothoracic and Vascular Anesthesia. 2014;28(4):896-9. https://doi.org/10.1053/j.jvca.2013.02.006
  • 6. Zhang H, Li Q. Clinical efficacy of disposcope endoscope in bronchial double-lumen tube intubation. Acta Academiae Medicinae Jiangxi. 2014;9:62-5.
  • 7. Zhang Z, Wang S, Qi B, Li F, Su Z, An L. Efficacy of endobronchial intubation with double-lumen tube using fiberoptic bronchoscope assisted by video laryngoscope. Chinese Journal of Anesthesiology. 2016;36(6): 740-3. https://doi.org /10.3760/cma.j.issn.0254-1416 .2016.06.024
  • 8. Park SO, Shin DH, Lee KR, Hong DY, Kim EJ, Baek KJ. Efficacy of the Disposcope endoscope, a new video laryngoscope, for endotracheal intubation in patients with cervical spine immo- bilisation by semirigid neck collar: comparison with the Macintosh laryngoscope using a simulation study on a manikin. Emergency Medicine Journal. 2013;30:270-4. https://doi.org/10.1136/emermed-2011-200899
  • 9. Li XH, Sun Z, He LL. Feasibility of comfortable and secure intu- bation achieved with the Disposcope endoscope or Macintosh laryngoscope for patients in whom glottis viewing is difficult. Genetics and Molecular Research. 2015;14:3694-701. https://doi.org/10.4238/2015.April.17.19
  • 10. Liu Z, Zhao L, Jia Q, Liang S, Yang X. A comparison of Disposcope endoscope and Fiberoptic bronchoscope during awake orotracheal intubation in obese patients with anticipated difficult airway: a prospective, randomized and controlled clinical trial. International Journal of Clinical and Experimental Medicine. 2018;11(9):9654-61.
  • 11. Kamburoğlu H, Özkan G, Purtuloğlu T, Atım A, Yetim M, İnce ME ve ark. Çift lümenli endotrakeal tüp pozisyonunun doğrulanmasında fiberoptik bronkoskop ile kablosuz video endoskopun disposcope® karşılaştırılması. GKDA Derg. 2014;20(3):149-53. https://doi.org/10.5222/GKDAD.2014.149
  • 12. Chen PT, Ting CK, Lee MY, Cheng HW, Chan KH, Chang WK. A randomised trial comparing real‐time doublelumen endobronchial tube placement with the Disposcope® with conventional blind placement. Anaesthesia. 2017;72(9):1097-106. https://doi.org/10.1111/anae.13984
  • 13. Campos JH, Kernstine KH. A comparison of a left-sided Broncho-Cath® with the torque control blocker Univent and the wire-guided blocker. Anesthesia&Analgesia. 2003;96(1):283-9. https://doi.org/10.1097/00000539-200301000-00056
APA Kara U, ince e, OZKAN G, Senkal S (2020). Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. , 10 - 16. 10.5222/GKDAD.2020.65983
Chicago Kara Umut,ince emin,OZKAN GOKHAN,Senkal Serkan Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. (2020): 10 - 16. 10.5222/GKDAD.2020.65983
MLA Kara Umut,ince emin,OZKAN GOKHAN,Senkal Serkan Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. , 2020, ss.10 - 16. 10.5222/GKDAD.2020.65983
AMA Kara U,ince e,OZKAN G,Senkal S Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. . 2020; 10 - 16. 10.5222/GKDAD.2020.65983
Vancouver Kara U,ince e,OZKAN G,Senkal S Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. . 2020; 10 - 16. 10.5222/GKDAD.2020.65983
IEEE Kara U,ince e,OZKAN G,Senkal S "Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement." , ss.10 - 16, 2020. 10.5222/GKDAD.2020.65983
ISNAD Kara, Umut vd. "Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement". (2020), 10-16. https://doi.org/10.5222/GKDAD.2020.65983
APA Kara U, ince e, OZKAN G, Senkal S (2020). Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi, 26(1), 10 - 16. 10.5222/GKDAD.2020.65983
Chicago Kara Umut,ince emin,OZKAN GOKHAN,Senkal Serkan Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi 26, no.1 (2020): 10 - 16. 10.5222/GKDAD.2020.65983
MLA Kara Umut,ince emin,OZKAN GOKHAN,Senkal Serkan Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi, vol.26, no.1, 2020, ss.10 - 16. 10.5222/GKDAD.2020.65983
AMA Kara U,ince e,OZKAN G,Senkal S Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi. 2020; 26(1): 10 - 16. 10.5222/GKDAD.2020.65983
Vancouver Kara U,ince e,OZKAN G,Senkal S Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement. Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi. 2020; 26(1): 10 - 16. 10.5222/GKDAD.2020.65983
IEEE Kara U,ince e,OZKAN G,Senkal S "Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement." Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi, 26, ss.10 - 16, 2020. 10.5222/GKDAD.2020.65983
ISNAD Kara, Umut vd. "Comparison of Fiberoptic Bronchoscope and ID Disposcope Endoscope in Cohen Endobronchial Blocker Placement". Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi 26/1 (2020), 10-16. https://doi.org/10.5222/GKDAD.2020.65983