Yıl: 2020 Cilt: 40 Sayı: 2 Sayfa Aralığı: 359 - 366 Metin Dili: İngilizce DOI: 10.47480/isibted.817094 İndeks Tarihi: 08-06-2021

EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY

Öz:
The Fukushima accident has proved that passive safety systems in reactors are necessary to avoid hydrogen accumulation. One of these systems are PAR (passive autocatalytic recombiner) to remove the hydrogen gases inside the containment in case of an accident. This paper aims to investigate a PAR device with catalyst sheets to calculate the hydrogen consumption, determine the temperature distribution, and PAR performance in the test facility. Test series were carried out in the test facility REKO-4 under atmospheric pressure and natural flow conditions. For the test purposes, hydrogen between 2.0 and 6.0 vol.% was injected into the vessel with the volumetric flow, 1.9 m3/h. The first rise in the temperature of the PAR inlet was found after 100 seconds of first hydrogen injection, this result demonstrated that hydrogen consumption started. The results from the test series showthat the PAR device can remove hydrogen and the PAR performance can be determined from the test results.
Anahtar Kelime:

REKO-4 TEST DÜZENEĞİNDE HİDROJEN REKOMBİNASYONU İÇİN PAR CİHAZININ DENEYSEL İNCELENMESİ

Öz:
Fukuşima kazası, hidrojen birikimini önlemek için reaktörlerdeki pasif güvenlik sistemlerinin gerekliolduğunu kanıtladı. Bu sistemlerden biri olan PAR (pasif otokatalitik rekombiner), bir kaza durumunda korumakabında oluşabilecek hidrojen gazlarının uzaklaştırılmasında kullanılır. Bu makalenin amacı, test düzeneğinde PARcihazının performansını ve sıcaklık dağılımını belirlemek, hidrojen tüketimini hesaplamak için katalizör levhalı birPAR cihazını araştırmaktır. Testler atmosferik basınç ve doğal akış şartları altında REKO-4 test düzeneğinde gerçekleştirildi. Test için, hacimce 2-6 % arasında hidrojen 1,9 m3 /h hacimsel debi ile kaba enjekte edildi. PARgirişinin sıcaklığındaki ilk artış, ilk hidrojen enjeksiyonundan 100 saniye sonra gerçekleşti, bu sonuç hidrojentüketiminin başladığını göstermektedir. Testlerden elde edilen sonuçlar, PAR cihazının hidrojeni tüketebildiğini vePAR performansının test sonuçlarından belirlenebileceğini göstermektedir.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • Bachellerie, E., Arnould F., Auglaire M. , Boeck B., Braillard O. ,Eckardt B. , Ferroni f F. , Moffett R. "Generic approach for designing and implementing a passive autocatalytic recombiner PAR-system in nuclear power plant containments." Nuclear Engineering and Design, 2003: 151-165.
  • Gupta, S. "experimental investigations relevant for hydrogen and fission product issues raised by the fukushima accident." Nuclear Engineering and Technology, 2015: 11-25.
  • Häfele, Cand. oec. Ing. Benjamin. "Realisierung und Vermessung einer abwärts gerichteten, wandnahen Gasströmung innerhalb des Versuchsstandes REKO-4." Thesis, 2012.
  • Reinecke, E., Kelm S., Jahn W., Jakel C., Allelein H. "Simulation of the efficiency of hydrogen recombiners as safety devices." International journal of hydrogen energy, 2013: 8117-8124.
  • Simon, B., Reinecke, E., Klauck,M., Heidelberg D., Allelein H.-J. "Investigation of PAR Behavior in the REKO-4 Test Facility." Proceedings of the 2012 20th International Conference on Nuclear Engineering. California, USA: ICONE20-POWER2012-54234, 2012.
  • Simon, B., Reinecke, E., Kubelt C., Allelein H. "Start up behaviour of a passive auto-catalytic recombiner undercounter flow conditions: Results of a first orienting experimentalstudy." Nuclear Engineering and Design, no. 278 (2014): 317-322.
APA KAHRAMAN M, Steffen P (2020). EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. , 359 - 366. 10.47480/isibted.817094
Chicago KAHRAMAN MAHMUT CÜNEYT,Steffen Paul EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. (2020): 359 - 366. 10.47480/isibted.817094
MLA KAHRAMAN MAHMUT CÜNEYT,Steffen Paul EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. , 2020, ss.359 - 366. 10.47480/isibted.817094
AMA KAHRAMAN M,Steffen P EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. . 2020; 359 - 366. 10.47480/isibted.817094
Vancouver KAHRAMAN M,Steffen P EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. . 2020; 359 - 366. 10.47480/isibted.817094
IEEE KAHRAMAN M,Steffen P "EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY." , ss.359 - 366, 2020. 10.47480/isibted.817094
ISNAD KAHRAMAN, MAHMUT CÜNEYT - Steffen, Paul. "EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY". (2020), 359-366. https://doi.org/10.47480/isibted.817094
APA KAHRAMAN M, Steffen P (2020). EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. Isı Bilimi ve Tekniği Dergisi, 40(2), 359 - 366. 10.47480/isibted.817094
Chicago KAHRAMAN MAHMUT CÜNEYT,Steffen Paul EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. Isı Bilimi ve Tekniği Dergisi 40, no.2 (2020): 359 - 366. 10.47480/isibted.817094
MLA KAHRAMAN MAHMUT CÜNEYT,Steffen Paul EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. Isı Bilimi ve Tekniği Dergisi, vol.40, no.2, 2020, ss.359 - 366. 10.47480/isibted.817094
AMA KAHRAMAN M,Steffen P EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. Isı Bilimi ve Tekniği Dergisi. 2020; 40(2): 359 - 366. 10.47480/isibted.817094
Vancouver KAHRAMAN M,Steffen P EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY. Isı Bilimi ve Tekniği Dergisi. 2020; 40(2): 359 - 366. 10.47480/isibted.817094
IEEE KAHRAMAN M,Steffen P "EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY." Isı Bilimi ve Tekniği Dergisi, 40, ss.359 - 366, 2020. 10.47480/isibted.817094
ISNAD KAHRAMAN, MAHMUT CÜNEYT - Steffen, Paul. "EXPERIMENTAL INVESTIGATION OF PAR DEVICE FOR HYDROGENRECOMBINATION IN REKO-4 FACILITY". Isı Bilimi ve Tekniği Dergisi 40/2 (2020), 359-366. https://doi.org/10.47480/isibted.817094