Yıl: 2020 Cilt: 28 Sayı: 4 Sayfa Aralığı: 228 - 231 Metin Dili: İngilizce DOI: 10.5336/caserep.2020-75626 İndeks Tarihi: 27-06-2021

Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy

Öz:
In the present study, it was reported a 23-year-old male patient, who presented with a penetrating eye injury, involving an anterior chamber reaction resistant to treatment after primary repair and, afterwards multiple glass fragments were detected with the help of gonioscopy at anterior chamber angle (ACA). We strongly suggest that biomicroscopic examination and imaging methods are insufficient toevaluate the presence of intraocular foreign bodies in patients with penetrating eye injuries. Therefore, ACA should be carefully screenedthrough gonioscopy. Although glass is an inert substance, it should be taken into consideration that it rarely causes treatment-resistant anterior chamber reaction.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Olgu Sunumu Erişim Türü: Erişime Açık
  • 1. Mester V, Kuhn F. Intraocular foreign bodies. Ophthalmol Clin North Am. 2002;15(2):235- 42.[Crossref] [PubMed]
  • 2. Loporchio D, Mukkamala L, Gorukanti K, Zarbin M, Langer P, Bhagat N. Intraocular foreign bodies: A review. Surv Ophthalmol. 2016;61(5):582-96.[Crossref] [PubMed]
  • 3. Stallard HB. The intra-ocular foreign body. A series of 72 cases in the B.L.A. Br J Ophthalmol. 1947;31(1):12-40.[Crossref] [PubMed] [PMC]
  • 4. Francis AW, Wu F, Zhu I, de Souza Pereira D, Bhisitkul RB. Glass intraocular foreign body removal with a nitinol stone basket. Am J Ophthalmol Case Rep. 2019;16:100541.[Crossref] [PubMed] [PMC]
  • 5. Ray S, Friberg TA, Beatty RR, Loewenstein J. Late posterior migration of glass intraocular foreign bodies. Arch Ophthalmol. 2004;122(6):923-6.[Crossref] [PubMed]
  • 6. Mostafavi D, Olumba K, Shrier EM. Fiberglass intraocular foreign body with no initial ocular symptoms. Retin Cases Brief Rep. 2014;8(1):10-2.[PubMed]
  • 7. Huang YM, Yan H, Cai JH, Li HB. Removal of intraocular foreign body in anterior chamber angle with prism contact lens and 23-gauge foreign body forceps. Int J Ophthalmol. 2017;10(5):749-53.[PubMed]
  • 8. Mete G, Turgut Y, Osman A, Gülşen u, Hakan A. Anterior segment intraocular metallic foreign body causing chronic hypopyon uveitis. J Ophthalmic Inflamm Infect. 2011;1(2):85- 7.[Crossref] [PubMed] [PMC]
  • 9. Wylegala E, Dobrowolski D, Nowińska A, Tarnawska D. Anterior segment optical coherence tomography in eye injuries. Graefes Arch Clin Exp Ophthalmol. 2009;247(4):451-5.[Crossref] [PubMed]
  • 10. Loporchio D, Mukkamala L, Gorukanti K, Zarbin M, Langer P, Bhagat N. Intraocular foreign bodies: A review. Surv Ophthalmol. 2016;61(5):582-96.[Crossref] [PubMed]
APA Balbaba M, dal a, Erdag M, YILDIRIM H, AYDEMİR O (2020). Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. , 228 - 231. 10.5336/caserep.2020-75626
Chicago Balbaba Mehmet,dal ali,Erdag Murat,YILDIRIM HAKAN,AYDEMİR Orhan Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. (2020): 228 - 231. 10.5336/caserep.2020-75626
MLA Balbaba Mehmet,dal ali,Erdag Murat,YILDIRIM HAKAN,AYDEMİR Orhan Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. , 2020, ss.228 - 231. 10.5336/caserep.2020-75626
AMA Balbaba M,dal a,Erdag M,YILDIRIM H,AYDEMİR O Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. . 2020; 228 - 231. 10.5336/caserep.2020-75626
Vancouver Balbaba M,dal a,Erdag M,YILDIRIM H,AYDEMİR O Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. . 2020; 228 - 231. 10.5336/caserep.2020-75626
IEEE Balbaba M,dal a,Erdag M,YILDIRIM H,AYDEMİR O "Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy." , ss.228 - 231, 2020. 10.5336/caserep.2020-75626
ISNAD Balbaba, Mehmet vd. "Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy". (2020), 228-231. https://doi.org/10.5336/caserep.2020-75626
APA Balbaba M, dal a, Erdag M, YILDIRIM H, AYDEMİR O (2020). Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. Türkiye Klinikleri Journal of Case Reports, 28(4), 228 - 231. 10.5336/caserep.2020-75626
Chicago Balbaba Mehmet,dal ali,Erdag Murat,YILDIRIM HAKAN,AYDEMİR Orhan Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. Türkiye Klinikleri Journal of Case Reports 28, no.4 (2020): 228 - 231. 10.5336/caserep.2020-75626
MLA Balbaba Mehmet,dal ali,Erdag Murat,YILDIRIM HAKAN,AYDEMİR Orhan Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. Türkiye Klinikleri Journal of Case Reports, vol.28, no.4, 2020, ss.228 - 231. 10.5336/caserep.2020-75626
AMA Balbaba M,dal a,Erdag M,YILDIRIM H,AYDEMİR O Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. Türkiye Klinikleri Journal of Case Reports. 2020; 28(4): 228 - 231. 10.5336/caserep.2020-75626
Vancouver Balbaba M,dal a,Erdag M,YILDIRIM H,AYDEMİR O Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy. Türkiye Klinikleri Journal of Case Reports. 2020; 28(4): 228 - 231. 10.5336/caserep.2020-75626
IEEE Balbaba M,dal a,Erdag M,YILDIRIM H,AYDEMİR O "Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy." Türkiye Klinikleri Journal of Case Reports, 28, ss.228 - 231, 2020. 10.5336/caserep.2020-75626
ISNAD Balbaba, Mehmet vd. "Diagnosing Misdiagnosed Anterior Chamber Angle Foreign Bodies by Gonioscopy". Türkiye Klinikleri Journal of Case Reports 28/4 (2020), 228-231. https://doi.org/10.5336/caserep.2020-75626