Öz:
OBJECTIVE: To determine the factors indicating the accuracy of fetal weight estimation in the last prenatal ultrasonography before delivery in preterm newborns with normal amniotic fluid volume.STUDY DESIGN: Three hundred and seventy-one singleton pregnancies with normal amniotic fluid volume and delivered at between 24+0 and 37+0 gestational weeks were evaluated in a retrospectivestudy. Any possible associations between the absolute percentage error of fetal weight estimations andthe maternal and fetal data were examined.RESULTS: In 135 of the 371 women (36%), the absolute percentage error was greater than 10%. Themean absolute percentage error was 8.7±7.5%. The mean absolute percentage errors were 4.1±2.7%and 16.8±6.4% in the accurate and inaccurate estimation groups, respectively.The rate of women examined during labor was significantly higher in the inaccurate estimation groupcompared to the accurate estimation group. There were no significant differences in age, body-massindex, gestational age at delivery, estimated-fetal-weight, actual birth weight, days from the last ultrasound examination to delivery, small for gestational age rate, placenta localization or fetal presentationbetween the two groups.Examination during labor (β=0.224) was the most important factor for the prediction of the absolute percentage error, followed by gestational age at delivery (β=–0.198), presence of (β=–0.158), and bodymass-index (β=0.142).CONCLUSION: In 36% of our study population, the absolute percentage error was >10%. Examinationduring labor was the most important factor for the prediction of the absolute percentage error, followedby gestational age at delivery, presence of small for gestational age, and body-mass-index.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Dudley NJ. A systematic review of the ultrasound estimation of fetal weight. Ultrasound Obstet Gynecol. 2005; 25(1):80-9. doi: 10.1002/uog.1751.
  • 2. Kurmanavicius J. Burkhardt T. Wisser J. Huch R. Ultrasonographic fetal weight estimation: accuracy of formulas and accuracy of examiners by birth weight from 500 to 5000 g. J Perinat Med. 2004;32(2):155-61. doi: 10.1515/JPM.2004.028.
  • 3. Siemer J. Egger N. Hart N. Meurer B. Müller A. Dathe O. et al. Fetal weight estimation by ultrasound: comparison of 11 different formulae and examiners with differing skill levels. Ultraschall Med. 2008;29(2):159-64. doi: 10.1515/ JPM.2004.028.
  • 4. Huber C. Zdanowicz JA. Mueller M. Surbek D. Factors influencing the accuracy of fetal weight estimation with a focus on preterm birth at the limit of viability: a systematic literature review. Fetal Diagn Ther. 2014;36(1):1-8. doi: 10.1159/000358518.
  • 5. Melamed N. Yogev Y. Ben-Haroush A. Meizner I. Mashiach R. Glezerman M. Does use of a sex-specific model improve the accuracy of sonographic weight estimation? Ultrasound Obstet Gynecol. 2012;39(5):549-57. doi: 10.1002/uog.10064.
  • 6. Berger TM. Bernet V. El Alama S. Fauchere JC. Hösli I. Irion O. et al. Perinatal care at the limit of viability between 22 and 26 completed weeks of gestation in Switzerland. 2011 revision of the Swiss recommendations. Swiss Med Wkly. 2011;141:w13280. doi: 10.4414/ smw.2011.13280.
  • 7. Tyson JE. Parikh NA. Langer J. Green C. Higgins RD. National Institute of Child Health and Human Development Neonatal Research Network. Intensive care for extreme prematurity - moving beyond gestational age. N Engl J Med. 2008;358(16):1672-81. doi:10.1056/ NEJMoa073059.
  • 8. Heer IM. Kumper C. Vogtle N. Muller-Egloff S. Dugas M. Strauss A. Analysis of factors influencing the ultrasonic fetal weight estimation. Fetal Diagn Ther. 2008;23 (3):204-10. doi: 10.1159/000116742.
  • 9. Mills MD. Nageotte MP. Elliott JP. Crade M. Dorchester W. Reliability of ultrasonographic formulary in the prediction of fetal weight and survival of very-low-birthweight infants. Am J Obstet Gynecol 1990;163(5 Pt 1): 1568-74. doi: 10.1016/0002-9378(90)90629-l.
  • 10. Edwards A. Goff J. Baker L. Accuracy and modifying factors of the sonographic estimation of fetal weight in a high-risk population. Aust N Z J Obstet Gynaecol. 2001; 41(2):187-90. doi: 10.1111/j.1479-828x.2001.tb01206.x.
  • 11. Ragosch V. Entezami M. Hundertmark S. Mutz A. Becker R. Weitzel H. Accuracy of ultrasound weight assessment- -comparison of vertex vs. breech presentation. Ultraschall Med. 1997;18(1):19-25. doi: 10.1055/s-2007-1000510.
  • 12. Melamed N. Ben-Haroush A. Meizner I. Mashiach R. Glezerman M. Yogev Y. Accuracy of sonographic weight estimation as a function of fetal sex. Ultrasound Obstet Gynecol. 2011;38(1):67-73. doi: 10.1002/uog.8914.
  • 13. Chauhan SP. Magann EF. Naef RW 3rd. Martin JN Jr. Morrison JC. Sonographic assessment of birth weight among breech presentations. Ultrasound Obstet Gynecol. 1995;6(1):54-7.doi:10.1046/j.1469-0705.1995. 06010054.x
  • 14. Faschingbauer F. Dammer U. Raabe E. Schneider M. Faschingbauer C. Schmid M. et al. Intrapartum sonographic weight estimation. Arch Gynecol Obstet. 2015; 292(4):805-11. doi: 10.1007/s00404-015-3720-3.
  • 15. Scott F. Beeby P. Abbott J. Accuracy of estimated fetal weight below 1,000 g. Aust N Z J Obstet Gynaecol. 1996; 36(2):129-32. doi: 10.1111/j.1479-828x.1996.tb03267.x.
  • 16. Shamley KT. Landon MB. Accuracy and modifying factors for ultrasonographic determination of fetal weight at term. Obstet Gynecol. 1994;84(6):926-30.
  • 17. Field NT. Piper JM. Langer O. The effect of maternal obesity on the accuracy of fetal weight estimation. Obstet Gynecol. 1995;86(1):102-7. doi: 10.1016/0029-7844(95) 00096-A.
  • 18. Farrell T1. Holmes R. Stone P. The effect of body mass index on three methods of fetal weight estimation. BJOG. 2002;109(6):651-7. doi: 10.1111/j.1471- 0528.2002.01249.x.
  • 19. Kaaij MW. Struijk PC. Lotgering FK. Accuracy of sonographic estimates of fetal weight in very small infants. Ultrasound Obstet Gynecol. 1999;13(2):99-102. doi: 10.1046/j.1469-0705.1999.13020099
APA Guralp O, Tüten N, TÜTEN A, GEZER A (2021). Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. , 17 - 21. 10.21613/GORM.2019.1012
Chicago Guralp Onur,Tüten Nevin,TÜTEN ABDULLAH,GEZER ALTAY Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. (2021): 17 - 21. 10.21613/GORM.2019.1012
MLA Guralp Onur,Tüten Nevin,TÜTEN ABDULLAH,GEZER ALTAY Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. , 2021, ss.17 - 21. 10.21613/GORM.2019.1012
AMA Guralp O,Tüten N,TÜTEN A,GEZER A Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. . 2021; 17 - 21. 10.21613/GORM.2019.1012
Vancouver Guralp O,Tüten N,TÜTEN A,GEZER A Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. . 2021; 17 - 21. 10.21613/GORM.2019.1012
IEEE Guralp O,Tüten N,TÜTEN A,GEZER A "Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume." , ss.17 - 21, 2021. 10.21613/GORM.2019.1012
ISNAD Guralp, Onur vd. "Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume". (2021), 17-21. https://doi.org/10.21613/GORM.2019.1012
APA Guralp O, Tüten N, TÜTEN A, GEZER A (2021). Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. GORM:Gynecology Obstetrics & Reproductive Medicine, 27(1), 17 - 21. 10.21613/GORM.2019.1012
Chicago Guralp Onur,Tüten Nevin,TÜTEN ABDULLAH,GEZER ALTAY Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. GORM:Gynecology Obstetrics & Reproductive Medicine 27, no.1 (2021): 17 - 21. 10.21613/GORM.2019.1012
MLA Guralp Onur,Tüten Nevin,TÜTEN ABDULLAH,GEZER ALTAY Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. GORM:Gynecology Obstetrics & Reproductive Medicine, vol.27, no.1, 2021, ss.17 - 21. 10.21613/GORM.2019.1012
AMA Guralp O,Tüten N,TÜTEN A,GEZER A Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. GORM:Gynecology Obstetrics & Reproductive Medicine. 2021; 27(1): 17 - 21. 10.21613/GORM.2019.1012
Vancouver Guralp O,Tüten N,TÜTEN A,GEZER A Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume. GORM:Gynecology Obstetrics & Reproductive Medicine. 2021; 27(1): 17 - 21. 10.21613/GORM.2019.1012
IEEE Guralp O,Tüten N,TÜTEN A,GEZER A "Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume." GORM:Gynecology Obstetrics & Reproductive Medicine, 27, ss.17 - 21, 2021. 10.21613/GORM.2019.1012
ISNAD Guralp, Onur vd. "Factors Indicating the Accuracy of Fetal Weight Estimation in Preterm Newborns with Normal Amniotic Fluid Volume". GORM:Gynecology Obstetrics & Reproductive Medicine 27/1 (2021), 17-21. https://doi.org/10.21613/GORM.2019.1012