Yıl: 2021 Cilt: 22 Sayı: 3 Sayfa Aralığı: 212 - 216 Metin Dili: İngilizce DOI: 10.5152/TurkThoracJ.2021.20032 İndeks Tarihi: 01-10-2021

Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease

Öz:
This study evaluated the relationship between end-tidal carbon dioxide (EtCO2) measured with a portable capnometer andPaCO2 in respiratory disease patients.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Fulmer JD, Roberts WC, von Gal ER, Crystal RG. Morphologicphysiologic correlates of the severity of fibrosis and degree of cellularity in idiopathic pulmonary fibrosis. J Clin Invest. 1979;63:665-676. [CrossRef]
  • 2. Gruffydd-Jones K, Jones MM. NICE guidelines for chronic obstructive pulmonary disease: implications for primary care. Br J Gen Pract. 2011;61:91-92. [CrossRef]
  • 3. Tsukuura H, Nishimura K, Taniguchi H et al. Opioid use in end-of-life care in patients with interstitial pneumonia associated with respiratory worsening. J Pain Palliat Care Pharmacother. 2013;27:214-219. [CrossRef]
  • 4. Uemasu K, Sato S, Muro S et al. Annual decline in arterial blood oxygen predicts development of chronic respiratory failure in COPD with mild hypoxaemia: a 6-year follow-up study. Respirology. 2019;24:262-269. [CrossRef]
  • 5. Berger A. Brachial artery puncture: the need for caution. J Fam Pract. 1989;28:720-721.
  • 6. Luce EA, Futrell JW, Wilgis EF, Hoopes JE. Compression neuropathy following brachial arterial puncture in anticoagulated patients. J Trauma. 1976;16:717-721. [CrossRef]
  • 7. Dar K, Williams T, Aitken R, Woods KL, Fletcher S. Arterial versus capillary sampling for analysing blood gas pressures. BMJ. 1995;310:24-25. [CrossRef]
  • 8. O'Driscoll BR, Howard LS, Davison AG. British Thoracic Society. BTS guideline for emergency oxygen use in adult patients. Thorax. 2008;63(suppl 6):vi1-vi68. [CrossRef]
  • 9. Takano Y, Sakamoto O, Kiyofuji C, Ito K. A comparison of the end-tidal CO2 measured by portable capnometer and the arterial PCO2 in spontaneously breathing patients. Respir Med. 2003;97:476-481. [CrossRef]
  • 10. Heidari K, Hatamabadi H, Ansarian N et al. Correlation between capillary and arterial blood gas parameters in an ED. Am J Emerg Med. 2013;31:326-329. [CrossRef]
  • 11. Barton CW, Wang ES. Correlation of end-tidal CO2 measurements to arterial PaCO2 in nonintubated patients. Ann Emerg Med. 1994;23:560-563. [CrossRef]
  • 12. Razi E, Moosavi GA, Omidi K, Khakpour Saebi A, Razi A. Correlation of end-tidal carbon dioxide with arterial carbon dioxide in mechanically ventilated patients. Arch Trauma Res. 2012;1:58-62. [CrossRef]
  • 13. Gaur P, Harde M, Gujjar P, Deosarkar D, Bhadade R. A study of partial pressure of arterial carbon dioxide and end-tidal carbon dioxide correlation in intraoperative and postoperative period in neurosurgical patients. Asian J Neurosurg. 2017;12:475-482. [CrossRef]
  • 14. Fujimoto S, Suzuki M, Sakamoto K et al. Comparison of endtidal, arterial, venous, and transcutaneous PCO2. Respir Care. 2019;64:1208-1214. [CrossRef]
  • 15. Kim KW, Choi HR, Bang SR, Lee JW. Comparison of end-tidal CO2 measured by transportable capnometer (EMMA capnograph) and arterial pCO2 in general anesthesia. J Clin Monit Comput. 2016;30(5):737-741. [CrossRef].
  • 16. Cinar O, Acar YA, Arziman I et al. Can mainstream end-tidal carbon dioxide measurement accurately predict the arterial carbon dioxide level of patients with acute dyspnea in ED. Am J Emerg Med. 2012;30:358-361. [CrossRef]
  • 17. Yamanaka MK, Sue DY. Comparison of arterial-end-tidal PCO2 difference and dead space/tidal volume ratio in respiratory failure. Chest. 1987;92:832-835. [CrossRef]
  • 18. Nagler J, Krauss B. Capnographic monitoring in respiratory emergencies. Clin Pediatr Emerg Med. 2009;10:82-89. [CrossRef]
  • 19. Taylor R. Interpretation of the correlation coefficient: A basic review. J Diagn Med Sonogr. 1990;6:35-39. [CrossRef]
  • 20. McSwain SD, Hamel DS, Smith PB et al. End-tidal and arterial carbon dioxide measurements correlate across all levels of physiologic dead space. Respir Care. 2010;55:288-293.
  • 21. Paul J, Ling E, Hajgato J, McDonald L. Both the OxyArm and Capnoxygen mask provide clinically useful capnographic monitoring capability in volunteers. Can J Anaesth. 2003;50:137- 142. [CrossRef]
APA Enomoto T, Matsuda Y, ADACHİ Y, Kouno S, Inagaki Y, Azuma K, 加奈子 片, Takeuchi N, Inoue Y (2021). Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. , 212 - 216. 10.5152/TurkThoracJ.2021.20032
Chicago Enomoto Takatoshi,Matsuda Yoshinobu,ADACHİ Yuichi,Kouno Shunichi,Inagaki Yuji,Azuma Koji,加奈子 片山,Takeuchi Naoko,Inoue Yoshikazu Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. (2021): 212 - 216. 10.5152/TurkThoracJ.2021.20032
MLA Enomoto Takatoshi,Matsuda Yoshinobu,ADACHİ Yuichi,Kouno Shunichi,Inagaki Yuji,Azuma Koji,加奈子 片山,Takeuchi Naoko,Inoue Yoshikazu Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. , 2021, ss.212 - 216. 10.5152/TurkThoracJ.2021.20032
AMA Enomoto T,Matsuda Y,ADACHİ Y,Kouno S,Inagaki Y,Azuma K,加奈子 片,Takeuchi N,Inoue Y Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. . 2021; 212 - 216. 10.5152/TurkThoracJ.2021.20032
Vancouver Enomoto T,Matsuda Y,ADACHİ Y,Kouno S,Inagaki Y,Azuma K,加奈子 片,Takeuchi N,Inoue Y Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. . 2021; 212 - 216. 10.5152/TurkThoracJ.2021.20032
IEEE Enomoto T,Matsuda Y,ADACHİ Y,Kouno S,Inagaki Y,Azuma K,加奈子 片,Takeuchi N,Inoue Y "Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease." , ss.212 - 216, 2021. 10.5152/TurkThoracJ.2021.20032
ISNAD Enomoto, Takatoshi vd. "Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease". (2021), 212-216. https://doi.org/10.5152/TurkThoracJ.2021.20032
APA Enomoto T, Matsuda Y, ADACHİ Y, Kouno S, Inagaki Y, Azuma K, 加奈子 片, Takeuchi N, Inoue Y (2021). Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. Turkish Thoracic Journal, 22(3), 212 - 216. 10.5152/TurkThoracJ.2021.20032
Chicago Enomoto Takatoshi,Matsuda Yoshinobu,ADACHİ Yuichi,Kouno Shunichi,Inagaki Yuji,Azuma Koji,加奈子 片山,Takeuchi Naoko,Inoue Yoshikazu Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. Turkish Thoracic Journal 22, no.3 (2021): 212 - 216. 10.5152/TurkThoracJ.2021.20032
MLA Enomoto Takatoshi,Matsuda Yoshinobu,ADACHİ Yuichi,Kouno Shunichi,Inagaki Yuji,Azuma Koji,加奈子 片山,Takeuchi Naoko,Inoue Yoshikazu Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. Turkish Thoracic Journal, vol.22, no.3, 2021, ss.212 - 216. 10.5152/TurkThoracJ.2021.20032
AMA Enomoto T,Matsuda Y,ADACHİ Y,Kouno S,Inagaki Y,Azuma K,加奈子 片,Takeuchi N,Inoue Y Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. Turkish Thoracic Journal. 2021; 22(3): 212 - 216. 10.5152/TurkThoracJ.2021.20032
Vancouver Enomoto T,Matsuda Y,ADACHİ Y,Kouno S,Inagaki Y,Azuma K,加奈子 片,Takeuchi N,Inoue Y Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease. Turkish Thoracic Journal. 2021; 22(3): 212 - 216. 10.5152/TurkThoracJ.2021.20032
IEEE Enomoto T,Matsuda Y,ADACHİ Y,Kouno S,Inagaki Y,Azuma K,加奈子 片,Takeuchi N,Inoue Y "Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease." Turkish Thoracic Journal, 22, ss.212 - 216, 2021. 10.5152/TurkThoracJ.2021.20032
ISNAD Enomoto, Takatoshi vd. "Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease". Turkish Thoracic Journal 22/3 (2021), 212-216. https://doi.org/10.5152/TurkThoracJ.2021.20032