Yıl: 2021 Cilt: 55 Sayı: 2 Sayfa Aralığı: 107 - 111 Metin Dili: İngilizce DOI: 10.5152/j.aott.2021.20114 İndeks Tarihi: 29-09-2021

Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis

Öz:
Objective: This study aims to investigate compensatory rotational movements of the wrist joint in patients with proximal congenital radioulnar synostosis (CRUS), using a valid and reliable three-dimensional (3D) motion analysis technique.Methods: A total of 26 patients (6 females, 14 males; mean age=15.3 years; and age range=6-32 years) who were diagnosed withunilateral proximal CRUS but were not operated were enrolled in this study. Patients were then categorized into 2 groups: GroupI included 5 patients younger than 10 years, and Group II included 15 patients older than 10 years. Eighteen light-reflective skinmarkers were placed on the bony landmarks of both upper limbs, and both distal forearms were fixed using a U-shaped device tominimize forearm rotation. Each patient grasped the handle of an instrument that used a goniometer to measure wrist rotation;maximal passive pronation and supination angles of the wrist were measured in this manner and also using 3D motion analysis.Results: There was a significant correlation between measurements by the goniometer and 3D motion analysis (r=0.985, p<0.001).The test-retest reliability of the 3D motion analysis was acceptable for both the affected side (ICC=0.992) and the contralateral normal side (ICC=0.997) with low standard measurement errors (1.3° and 0.8°, respectively). Although no significant difference wasobserved in the range of the wrist rotation between the affected and contralateral sides in Group I (p=0.686), there was a significantdifference in the wrist rotation between the affected and contralateral sides in Group II (p=0.001). Further, the pronation angle of thewrist joint was significantly larger in the affected side than that in the contralateral normal side in Group II (p=0.001).Conclusion: The 3D motion analysis technique seems to be a valid and reliable method to measure the rotation of the wrist joint.Unilateral proximal CRUS patients older than 10 years of age may develop rotational hypermobility of the wrist joint comparedto the contralateral normal side as a compensatory phenomenon.Level of Evidence: Level III, Diagnostic Study
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Bibliyografik
  • 1. Murase T, Tada K, Yoshida T, Moritomo H. Derotational osteotomy at the shafts of the radius and ulna for congenital radioulnar synostosis. J Hand Surg Am 2003; 28: 133-7.
  • 2. Green WT, Mital MA. Congenital radio-ulnar synostosis: surgical treatment. J Bone Joint Surg Am 1979; 61: 738-43.
  • 3. Lin HH, Strecker WB, Manske PR, Schoenecker PL, Seyer DM. A surgical technique of radioulnar osteoclasis to correct severe forearm rotation deformities. J Pediatr Orthop 1995; 15: 53-8.
  • 4. Hung NN. Derotational osteotomy of the proximal radius and the distal ulna for congenital radioulnar synostosis. J Child Orthop 2008; 2: 481-9.
  • 5. Simcock X, Shah AS, Waters PM, Bae DS. Safety and efficacy of derotational osteotomy for congenital radioulnar synostosis. J Pediatr Orthop 2015; 35: 838- 43.
  • 6. Horii E, Koh S, Hattori T, Otsuka J. Single osteotomy at the radial diaphysis for congenital radioulnar synostosis. J Hand Surg Am 2014; 39: 1553-7.
  • 7. Fujimoto M, Kato H, Minami A. Rotational osteotomy at the diaphysis of the radius in the treatment of congenital radioulnar synostosis. J Pediatr Orthop 2005; 25: 676-9.
  • 8. Ogino T, Hikino K. Congenital radio-ulnar synostosis: compensatory rotation around the wrist and rotation osteotomy. J Hand Surg Br 1987; 12: 173-8.
  • 9. Yammine K, Salon A, Pouliquen JC. Congenital radioulnar synostosis. Study of a series of 37 children and adolescents. Chir Main 1998; 17: 300-8.
  • 10. Kasten P, Rettig O, Loew M, Wolf S, Raiss P. Three-dimensional motion analysis of compensatory movements in patients with radioulnar synostosis performing activities of daily living. J Orthop Sci 2009; 14: 307-12.
  • 11. Cleary JE, Omer GE, Jr. Congenital proximal radio-ulnar synostosis. Natural history and functional assessment. J Bone Joint Surg Am 1985; 67: 539-45.
  • 12. Rab G, Petuskey K, Bagley A. A method for determination of upper extremity kinematics. Gait Posture 2002; 15: 113-9.
  • 13. Weir PJ. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 2005; 19: 231-40.
  • 14. Simmons BP, Southmayd WW, Riseborough EJ. Congenital radioulnar synostosis. J Hand Surg Am 1983; 8: 829-38.
  • 15. Antonio DH, Magalhaes CS. Survey on joint hypermobility in university students aged 18-25 years old. Adv Rheumatol 2018; 58: 3.
  • 16. Ritt MJ, Stuart PR, Berglund LJ, et al. Rotational laxity and stiffness of the radiocarpal joint. Clin Biomech (Bristol, Avon) 1996; 11: 227-32.
  • 17. Nakasone M, Nakasone S, Kinjo M, Murase T, Kanaya F. Three-dimensional analysis of deformities of the radius and ulna in congenital proximal radioulnar synostosis. J Hand Surg Eur Vol 2018; 43: 739-43.
APA LI Q, Park J, Lee Y, Kim J, Bae K, Baek G (2021). Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. , 107 - 111. 10.5152/j.aott.2021.20114
Chicago LI QINGYUAN,Park Jay Hoon,Lee Yohan,Kim Jihyeung,Bae Kee Jeong,Baek Goo Hyun Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. (2021): 107 - 111. 10.5152/j.aott.2021.20114
MLA LI QINGYUAN,Park Jay Hoon,Lee Yohan,Kim Jihyeung,Bae Kee Jeong,Baek Goo Hyun Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. , 2021, ss.107 - 111. 10.5152/j.aott.2021.20114
AMA LI Q,Park J,Lee Y,Kim J,Bae K,Baek G Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. . 2021; 107 - 111. 10.5152/j.aott.2021.20114
Vancouver LI Q,Park J,Lee Y,Kim J,Bae K,Baek G Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. . 2021; 107 - 111. 10.5152/j.aott.2021.20114
IEEE LI Q,Park J,Lee Y,Kim J,Bae K,Baek G "Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis." , ss.107 - 111, 2021. 10.5152/j.aott.2021.20114
ISNAD LI, QINGYUAN vd. "Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis". (2021), 107-111. https://doi.org/10.5152/j.aott.2021.20114
APA LI Q, Park J, Lee Y, Kim J, Bae K, Baek G (2021). Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. Acta Orthopaedica et Traumatologica Turcica, 55(2), 107 - 111. 10.5152/j.aott.2021.20114
Chicago LI QINGYUAN,Park Jay Hoon,Lee Yohan,Kim Jihyeung,Bae Kee Jeong,Baek Goo Hyun Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. Acta Orthopaedica et Traumatologica Turcica 55, no.2 (2021): 107 - 111. 10.5152/j.aott.2021.20114
MLA LI QINGYUAN,Park Jay Hoon,Lee Yohan,Kim Jihyeung,Bae Kee Jeong,Baek Goo Hyun Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. Acta Orthopaedica et Traumatologica Turcica, vol.55, no.2, 2021, ss.107 - 111. 10.5152/j.aott.2021.20114
AMA LI Q,Park J,Lee Y,Kim J,Bae K,Baek G Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. Acta Orthopaedica et Traumatologica Turcica. 2021; 55(2): 107 - 111. 10.5152/j.aott.2021.20114
Vancouver LI Q,Park J,Lee Y,Kim J,Bae K,Baek G Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis. Acta Orthopaedica et Traumatologica Turcica. 2021; 55(2): 107 - 111. 10.5152/j.aott.2021.20114
IEEE LI Q,Park J,Lee Y,Kim J,Bae K,Baek G "Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis." Acta Orthopaedica et Traumatologica Turcica, 55, ss.107 - 111, 2021. 10.5152/j.aott.2021.20114
ISNAD LI, QINGYUAN vd. "Measurement of compensatory wrist joint rotation using three-dimensional motion analysis in patients with unilateral proximal congenital radioulnar synostosis". Acta Orthopaedica et Traumatologica Turcica 55/2 (2021), 107-111. https://doi.org/10.5152/j.aott.2021.20114