Yıl: 2021 Cilt: 51 Sayı: 6 Sayfa Aralığı: 2959 - 2967 Metin Dili: İngilizce DOI: 10.3906/sag-2101-166 İndeks Tarihi: 05-01-2022

Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography

Öz:
Background/aim: To evaluate benign and malignant cutaneous-subcutaneous lesions using real-time strain elastography (RTSE) and to compare the findings with histopathologic results. Materials and methods: Over a period of 10 months, 72 patients (38 with benign and 34 with malignant cutaneous and subcutaneous lesions) were prospectively included in this study. Elasticity patterns and strain ratios were examined for each lesion. Lesions were evaluated in 4 groups as yellow-red (soft; pattern-1), green-yellow (moderate; pattern-2), blue-green (hard; pattern-3) and blue (hardest; pattern-4). The stiffness of the lesions was displayed with strain ratios by comparing of a nearby reference tissue. The recorded images were compared with histopathologic findings. Results: On sonoelastograms, considering patterns 1-2 as benign and patterns 3-4 as malignant, the sensitivity, specificity, and positive and negative predictive values for the differentiation of malignant from benign lesions were 100%, 68.5%, 74%, and 100%, respectively. Considering a cut-off value of the strain ratio as > 3.05, the sensitivity, specificity, and positive and negative predictive values were 91%, 89%, 88%, and 92%, respectively. The area under the curve (AUC: 0.972) showed the excellent ability of strain elastography to differentiate benign and malignant lesions. Conclusion: RTSE is an important imaging tool to differentiate benign and malignant superficial soft tissue lesions. Our results suggest that RTSE can be used to predict malignancy since malignant lesions are more confidentially diagnosed than benign superficial soft tissue lesions on elastograms.Key words: Benign, malignant, cutaneous, subcutaneous, real-time strain elastography
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Hu X, Huang X, Chen H, Zhang T, Hou J et al. Diagnostic effect of shear wave elastography imaging for differentiation of malignant liver lesions: a meta-analysis. BMC Gastroenterology 2019; 19 (1): 60. doi: 10.1186/s12876-019-0976-2
  • 2. Ferraioli G. Review of liver elastography guidelines. Journal of Ultrasound in Medicine 2019; 38 (1): 9-14. doi: 10.1002/ jum.14856
  • 3. Ophir J, Garra B, Kallel F, Konofagou E, Krouskop T et al. Elastographic imaging. Ultrasound in Medicine and Biology 2000; 26 (1): 23-29. doi: 10.1016/s0301-5629(00)00156-3
  • 4. Ophir J, Cespedes I, Ponnekanti H, Yazdi Y, Li X. Elastography: a quantitative method for imaging the elasticity of biological tissues. Ultrasonic Imaging 1991; 13 (2): 111–134. doi: 10.1177/016173469101300201
  • 5. Zaleska-Dorobisz U, Kaczorowski K, Pawluś A, Puchalska A, Inglot M. Ultrasound elastography- Review of techniques and its clinical applications. Advances in Clinical and Experimental Medicine 2014; 23 (4): 645-655. doi: 10.17219/acem/26301
  • 6. Krouskop TA, Wheeler TM, Kallel F, Garra BS, Hall T. Elastic moduli of breast and prostate tissues under compression. Ultrasonic Imaging 1998; 20 (4): 260-274. doi: 10.1177/016173469802000403
  • 7. Dudea SM, Botar-Jid C, Dumitriu D, Vasilescu D, Manole S et al. Differentiating benign from malignant superficial lymph nodes with sonoelastography. Medical Ultrasonography 2013; 15 (2): 132-139. doi: 10.11152/mu.2013.2066.152.smd1cbj2
  • 8. Wu CH, Chang KV, Mio S, Chen WS, Wang TG. Sonoelastography of the plantar fascia. Radiology 2011; 259 (2): 502-507. doi: 10.1148/radiol.11101665
  • 9. Baloji A, Chandra R, Bagri N, Misra R, Rajni K et al. Diagnostic accuracy of an integrated approach using conventional ultrasonography, and Doppler and strain elastography in the evaluation of superficial soft tissue lesions. Polish Journal of Radiology 2020; 85: 293-300. doi: 10.5114/pjr.2020.96961
  • 10. Onol S, Ozkaya O. Diagnostic Value of Real-Time Elastography in Diagnosing Lymph Node Metastasis of Skin Cancer. Cureus 2020; 12 (10): 10997. doi: 10.7759/cureus.10997
  • 11. Li A, Peng XJ, Ma Q, Dong Y, Mao CL et al. Diagnostic performance of conventional ultrasound and quantitative and qualitative real-time shear wave elastography in musculoskeletal soft tissue tumors. Journal of Orthopaedic Surgery and Research 2020; 15 (1): 103. doi: 10.1186/s13018- 020-01620-x
  • 12. Winn N, Baldwin J, Cassar-Pullicino V, Cool P, Ockendon M et al. Characterization of soft tissue tumours with ultrasound, shear wave elastography and MRI. Skeletal Radiology 2020; 49 (6): 869-881. doi: 10.1007/s00256-019-03363-1
  • 13. Burnside ES, Hall TJ, Sommer AM, Hesley GK, Sisney GA et al. Differentiating benign from malignant solid breast masses with US strain imaging. Radiology 2007; 245 (2): 401-410. doi: 10.1148/radiol.2452061805
  • 14. Magarelli N, Carducci C, Bucalo C, Filograna L, Rapisarda S et al. Sonoelastography for qualitative and quantitative evaluation of superficial soft tissue lesions: a feasibility study. Europian Radiology 2014; 24 (3): 566-573. doi: 10.1007/s00330-013- 3069-6
  • 15. Wu M, Ren A, Xu D, Peng X, Ye X et al. Diagnostic Performance of Elastography in Malignant Soft Tissue Tumors: A Systematic Review and Meta-analysis. Ultrasound in Medicine & Biology 2021; 47 (4): 855-868. doi: 10.1016/j.ultrasmedbio.2020.12.017
  • 16. Cohen J, Riishede I, Carlsen JF, Lambine TL, Dam MS et al. Can Strain Elastography Predict Malignancy of Soft Tissue Tumors in a Tertiary Sarcoma Center? Diagnostics (Basel) 2020; 10 (3): 148. doi: 10.3390/diagnostics10030148
  • 17. Tavare AN, Alfuraih AM, Hensor EMA, Astrinakis E, Gupta H et al. Shear-Wave Elastography of Benign versus Malignant Musculoskeletal Soft-Tissue Masses: Comparison with Conventional US and MRI. Radiology 2019; 290 (2): 410-417. doi: 10.3390/diagnostics10030148
  • 18. Dasgeb B, Morris MA, Mehregan D, Siegel EL. Quantified ultrasound elastography in the assessment of cutaneous carcinoma. The British Journal of Radiology 2015; 88 (1054): 20150344. doi: 10.1259/bjr.20150344
  • 19. Ozturk M, Selcuk MB, Polat AV, Ozbalci AB, Baris YS. The diagnostic value of ultrasound and shear wave elastography in the differentiation of benign and malignant soft tissue tumors. Skeletal Radiology 2020; 49 (11): 1795-1805. doi: 10.1007/ s00256-020-03492-y
  • 20. Zaĭtsev AN, Semënov II. Elastographic visualization of soft tissue tumors and its role in the diagnostic process. Voprosy Onkologii 2012; 58 (4): 564-567.
  • 21. Lee YH, Song HT, Suh JS. Use of strain ratio in evaluating superficial soft tissue tumors on ultrasonic elastography. Medical Ultrasonography 2014; 41 (3): 319-323. doi: 10.1007/ s10396-014-0528-x
  • 22. Friedrich-Rust M, Ong MF, Herrmann E, Dries V, Samaras P et al. Real-time elastography for noninvasive assessment of liver fibrosis in chronic viral hepatitis. American Journal of Roentgenology 2007; 188 (3): 758-764. doi: 10.2214/ AJR.06.0322
  • 23. Ferraioli G, Tinelli C, Malfitano A, Dal Bello B, Filice G et al. Performance of real-time strain elastography, transient elastography, and aspartate-to-platelet ratio index in the assessment of fibrosis in chronic hepatitis C. American Journal of Roentgenology 2012; 199 (1): 19-25. doi: 10.2214/ AJR.11.7517
  • 24. Patel K, Sellars ME, Clarke JL, Sidhu PS. Features of testicular epidermoid cysts on contrast-enhanced sonography and realtime tissue elastography. Journal of Ultrasound in Medicine 2012; 31 (1): 115-122. doi: 10.7863/jum.2012.31.1.115
  • 25. Yeoh HJ, Kim TY, Ryu JA. The feasibility of shear wave elastography for diagnosis of superficial benign soft tissue masses. Ultrasonography 2019; 38 (1): 37-43. doi: 10.14366/ usg.17059
  • 26. Bhatia KS, Rasalkar DP, Lee YP, Wong KT, King AD et al. Cystic change in thyroid nodules: a confounding factor for real-time qualitative thyroid ultrasound elastography. Clinical Radiology 2011; 66 (9): 799-807. doi: 10.1016/j.crad.2011.03.011
  • 27. Lyshchik A, Higashi T, Asato R, Tanaka S, Ito J et al. Thyroid gland tumor diagnosis at US elastography. Radiology 2005; 237 (1): 202–211. doi: 10.1148/radiol.2363041248
APA Annac G, CANYIGIT M, Tan S, Aksam E, Sungu N, ARSLAN H (2021). Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. , 2959 - 2967. 10.3906/sag-2101-166
Chicago Annac Gokce,CANYIGIT MURAT,Tan Sinan,Aksam Ersin,Sungu Nuran,ARSLAN HALIL Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. (2021): 2959 - 2967. 10.3906/sag-2101-166
MLA Annac Gokce,CANYIGIT MURAT,Tan Sinan,Aksam Ersin,Sungu Nuran,ARSLAN HALIL Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. , 2021, ss.2959 - 2967. 10.3906/sag-2101-166
AMA Annac G,CANYIGIT M,Tan S,Aksam E,Sungu N,ARSLAN H Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. . 2021; 2959 - 2967. 10.3906/sag-2101-166
Vancouver Annac G,CANYIGIT M,Tan S,Aksam E,Sungu N,ARSLAN H Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. . 2021; 2959 - 2967. 10.3906/sag-2101-166
IEEE Annac G,CANYIGIT M,Tan S,Aksam E,Sungu N,ARSLAN H "Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography." , ss.2959 - 2967, 2021. 10.3906/sag-2101-166
ISNAD Annac, Gokce vd. "Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography". (2021), 2959-2967. https://doi.org/10.3906/sag-2101-166
APA Annac G, CANYIGIT M, Tan S, Aksam E, Sungu N, ARSLAN H (2021). Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. Turkish Journal of Medical Sciences, 51(6), 2959 - 2967. 10.3906/sag-2101-166
Chicago Annac Gokce,CANYIGIT MURAT,Tan Sinan,Aksam Ersin,Sungu Nuran,ARSLAN HALIL Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. Turkish Journal of Medical Sciences 51, no.6 (2021): 2959 - 2967. 10.3906/sag-2101-166
MLA Annac Gokce,CANYIGIT MURAT,Tan Sinan,Aksam Ersin,Sungu Nuran,ARSLAN HALIL Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. Turkish Journal of Medical Sciences, vol.51, no.6, 2021, ss.2959 - 2967. 10.3906/sag-2101-166
AMA Annac G,CANYIGIT M,Tan S,Aksam E,Sungu N,ARSLAN H Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. Turkish Journal of Medical Sciences. 2021; 51(6): 2959 - 2967. 10.3906/sag-2101-166
Vancouver Annac G,CANYIGIT M,Tan S,Aksam E,Sungu N,ARSLAN H Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography. Turkish Journal of Medical Sciences. 2021; 51(6): 2959 - 2967. 10.3906/sag-2101-166
IEEE Annac G,CANYIGIT M,Tan S,Aksam E,Sungu N,ARSLAN H "Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography." Turkish Journal of Medical Sciences, 51, ss.2959 - 2967, 2021. 10.3906/sag-2101-166
ISNAD Annac, Gokce vd. "Differentiation of benign and malignant superficial soft tissue lesions using real-time strain elastography". Turkish Journal of Medical Sciences 51/6 (2021), 2959-2967. https://doi.org/10.3906/sag-2101-166