Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure

Öz:
Objective: Data on the umbilical cord and postnatal physiological limits of the high sensitivity cardiac troponin T (hs cTnT) in newborns are scarce. This study aims to determine the normal values and upper limits of hs cTnT in healthy newborns. In addition, its clinical significance and usability in neonatal respiratory failure were analyzed. Method: In this non-invasive and retrospective, cross-sectional study, 113 healthy newborns and 93 newborns with non-cardiac respiratory failure, born between July 2018 and January 2020, were evaluated. Hs cTnT was measured in the umbilical cord and 24-96 h after birth in infants. Results: In the healthy group, the median umbilical cord hs cTnT was 38 (17-156) ng/L and 99th percentile hs cTnT was 122 ng/L, and in the respiratory failure group, the median umbilical cord hs cTnT was 72 (27- 326) ng/L. Postnatal day 2-4 median hs cTnT was 75 (10-194) ng/L and 99th percentile value was 194 ng/L in the healthy group, and the median hs cTnT was 145 (41-409) ng/L in the respiratory failure group. The calculated area under the ROC curve for umbilical cord hs cTnT was 0.848 [cut-off: 64, 95% confidence interval (CI): 0.79-0.90, sensitivity: 62.4%, specificity: 93.7%], suggesting that umbilical cord hs cTnT is a sensitive marker for the prediction of neonatal respiratory failure. The calculated area under the ROC curve for control hs cTnT was 0.851 (cut-off: 121.5, 95% CI: 0.79- 0.90, sensitivity: 71%, specificity: 86.8%), suggesting that control hs cTnT is a sensitive marker for the prediction of neonatal respiratory failure. Conclusion: The results show that the reference range of umbilical cord and postnatal hs cTnT in healthy newborns is higher than that in adults. Both hs cTnT values were higher in the neonatal respiratory failure group than those in the healthy group.
Anahtar Kelime:

Sağlıklı Yenidoğanlarda ve Solunum Yetmezliği Olan Yenidoğanlarda Ardışık İki Yüksek Duyarlılıklı Kardiyak Troponin T Ölçümünün Değerlendirilmesi

Öz:
Amaç: Yenidoğanlarda yüksek duyarlılıklı kardiyak Troponin T’nin (hs cTnT) göbek kordonu ve doğum sonrası fizyolojik sınırlarına ilişkin veriler azdır. Bu çalışma sağlıklı yenidoğanlarda hs cTnT’nin normal değerlerini ve üst sınırlarını belirlemeyi amaçlamaktadır. Ayrıca, yenidoğan solunum yetmezliğinde klinik önemi ve kullanılabilirliği analiz edilmiştir. Yöntem: Bu invazif olmayan ve retrospektif, kesitsel çalışmada, Temmuz 2018 ile Ocak 2020 tarihleri arasında doğan 113 sağlıklı yenidoğan ve kalp dışı kaynaklı solunum yetmezliği olan 93 yenidoğan değerlendirildi. Hs cTnT, bebeklerde göbek kordonunda ve doğumdan 24-96 saat sonra ölçüldü. Bulgular: Sağlıklı grupta umbilikal kord hs cTnT medyan 38 (17-156) ng/L; 99. persantil hs cTnT 122 ng/L, solunum yetmezliği grubunda umbilikal kord hs cTnT medyan 72 (27-326) ng/L bulundu. Sağlıklı grupta postnatal 2-4 gün hs cTnT medyan 75 (10-194) ng/L; 99. persantil 194 ng/L, solunum yetmezliği grubunda hs cTnT medyan 145 (41-409) idi. Göbek kordonu için hs cTnT ROC eğrisi eğrinin altındaki alan değeri 0,848 [cut-off 64: %95 güven aralığı (GA): 0,79-0,90, duyarlılık: %62,4, özgüllük: %93,7], göbek kordonu hs cTnT’nin yenidoğan solunum yetmezliğinin tahmini için duyarlı bir belirteç olduğunu düşündürmektedir. Kontrol hs cTnT ROC eğrisi eğrinin altındaki alan değeri 0,851 (cut-off: 121,5, %95 GA: 0,79-0,90, duyarlılık: %71, özgüllük: %86,8), kontrol hs cTnT’nin neonatal solunum yetmezliğinin tahmini için duyarlı bir belirteç olduğunu göstermektedir. Sonuç: Sağlıklı yenidoğanlarda umbilikal kord ve postnatal hs cTnT referans aralığının, erişkin değerlerine göre yüksek olduğu saptanmıştır. Her iki hs cTnT değeri, yenidoğan solunum yetmezliği grubunda sağlıklı gruba göre çok artmıştır
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Bettencourt P. NT-proBNP and BNP: biomarkers for heart failure management. Eur J Heart Fail 2004;6(3):359-363.
  • 2. Bhayana V, Henderson AR. Biochemical markers of myocardial damage. Clin Biochem 1995;28(1):1-29.
  • 3. Simovic A, Stojkovic A. Correlation level of cardiac troponin-i with total duration of oxygen / ventilator therapy in the term newborns with respiratory distress. J Cardiovasc Dis Diagn 2014;2:5.
  • 4. Braunwald E, Fauci AS, Kasper DL. Harrison’s Principles of Internal Medicine, 15th ed. New York: McGraw-Hill; 2001.
  • 5. Clark SJ, Newland P, Yoxall CW, Subhedar NV. Cardiac troponin T in cord blood. Arch Dis Child Fetal Neonatal Ed 2001;84(1):F34-F37.
  • 6. Jehlicka P, Huml M, Rajdl D, Mockova A, Matas M, Dort J, et al. How to interpret elevated plasmatic level of high-sensitive troponin T in newborns and infants? Physiol Res 2018;67(2):191-195.
  • 7. Clark SJ, Newland P, Yoxall CW, Subhedar NV. Concentrations of cardiac troponin T in neonates with and without respiratory distress. Arch Dis Child Fetal Neonatal Ed 2004;89(4):F348-F52.
  • 8. Joseph S, Kumar S, Ahamed MZ, Lakshmi S. Cardiac troponin T as a marker of myocardial dysfunction in term neonates with perinatal asphyxia. Indian J Pediatr 2018;85(10):877-884.
  • 9. El-Khuffash AF, Molloy EJ. Influence of a patent ductus arteriosus on cardiac troponin T levels in preterm infants. J Pediatr 2008;153(3):350-353.
  • 10. Thygesen K, Alpert JS, Jaffe AS, Chaitman BR, Bax JJ, Morrow DA, et al; Executive Group on behalf of the Joint European Society of Cardiology (ESC)/American College of Cardiology (ACC)/ American Heart Association (AHA)/World Heart Federation (WHF) Task Force for the Universal Definition of Myocardial Infarction. Fourth universal definition of myocardial infarction (2018). Circulation 2018;138(20):e618-e651.
  • 11. Sweet DG, Carnielli V, Greisen G, Hallman M, Ozek E, Te Pas A, et al. European Consensus Guidelines on the management of respiratory distress syndrome - 2019 update. Neonatology 2019;115(4):432-450.
  • 12. Giannitsis E, Kurz K, Hallermayer K, Jarausch J, Jaffe AS, Katus HA. Analytical validation of a high-sensitivity cardiac troponin T assay. Clin Chem 2010;56(2):254-261.
  • 13. Awada H, Al-Tannir M, Ziade MF, Alameh J, El Rajab M. Cardiac troponin T: a useful early marker for cardiac and respiratory dysfunction in neonates. Neonatology 2017;92(2):105-110.
  • 14. Karlén J, Karlsson M, Eliasson H, Bonamy AE, Halvorsen CP. Cardiac troponin t in healthy full-term ınfants. Pediatr Cardiol 2019;40(8):1645-1654.
  • 15. Baum H, Hinze A, Bartels P, Neumeier D. Reference values for cardiac troponins T and I in healthy neonates. Clin Biochem 2004;37(12):1079-1082.
  • 16. Trevisanuto D, Zaninotto M, Altinier S, Plebani M, Zanardo V. High serum cardiac troponin T concentrations in preterm infants with respiratory distress syndrome. Acta Paediatr 2000;89(9):1134-1146.
  • 17. Fortunato G, Ciarrusso GP, Martinelli P, Sglavo G, Vassallo M, Tomeo L, et al. Cardiac troponin T and amino-terminal pro-natriuretic peptide concentrations in fetuses in the second trimester and in healthy neonates. Clin Chem Lab Med 2006;44(7):834-836.
  • 18. Remppis A, Scheffold T, Greten J. Intracellular compartmentation of troponin T: release kinetics after global ischaemia and calcium paradox in the isolated perfused rat heart. J Moll Cell Cardiol 1995;27(2):793-803.
  • 19. Shiva R, Maryam R, Hajie B. Cardiac troponin T levels of umbilical cord in neonates with abnormal fetal heart rate. Iran J Pediatr 2013;23(1):85-88.
  • 20. Lipshultz SE, Simbre VC, Hart S, Rifai N, Lipsitz SR, Reubens L, et al. Frequency of elevations in markers of cardiomyocyte damage in otherwise healthy newborns. Am J Cardiol 2008;102(6):761-766.
  • 21. El-Khuffash AF, Molly AJ. Serum troponin in neonatal intensive care. Neonatology 2008;94(1):1-7.
  • 22. Fahmeya SS, Fathya H, Gabalb KA, Khairya H. Cardiac troponin T in neonates with respiratory distress. Gaz Egypt Paediatr Assoc 2018;66(4):100-102.
  • 23. Anderson PA, Greig A, Mark T, Malouf NN, Oakeley AE, Ungerleider RM, et al. Molecular basis of human cardiac troponin T isoforms expressed in the developing, adult, and failing heart. Circ Res 1995;76(4):681-686.
  • 24. Rivara MB, Bajwa EK, Januzzi JL, Gong MN, Thompson BT, Christiani DC. Prognostic significance of elevated cardiac troponin-T levels in acute respiratory distress syndrome patients. PLoS One 2012;7(7):e40515.
APA TÜFEKCİ S, KIZILCA O, ÇELIKKOL A, Topçu B (2021). Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. , 287 - 294. 10.4274/BMB.galenos.2021.04.041
Chicago TÜFEKCİ SİNAN,KIZILCA OZGUR,ÇELIKKOL ALIYE,Topçu Birol Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. (2021): 287 - 294. 10.4274/BMB.galenos.2021.04.041
MLA TÜFEKCİ SİNAN,KIZILCA OZGUR,ÇELIKKOL ALIYE,Topçu Birol Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. , 2021, ss.287 - 294. 10.4274/BMB.galenos.2021.04.041
AMA TÜFEKCİ S,KIZILCA O,ÇELIKKOL A,Topçu B Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. . 2021; 287 - 294. 10.4274/BMB.galenos.2021.04.041
Vancouver TÜFEKCİ S,KIZILCA O,ÇELIKKOL A,Topçu B Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. . 2021; 287 - 294. 10.4274/BMB.galenos.2021.04.041
IEEE TÜFEKCİ S,KIZILCA O,ÇELIKKOL A,Topçu B "Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure." , ss.287 - 294, 2021. 10.4274/BMB.galenos.2021.04.041
ISNAD TÜFEKCİ, SİNAN vd. "Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure". (2021), 287-294. https://doi.org/10.4274/BMB.galenos.2021.04.041
APA TÜFEKCİ S, KIZILCA O, ÇELIKKOL A, Topçu B (2021). Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. Bağcılar Tıp Bülteni, 6(3), 287 - 294. 10.4274/BMB.galenos.2021.04.041
Chicago TÜFEKCİ SİNAN,KIZILCA OZGUR,ÇELIKKOL ALIYE,Topçu Birol Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. Bağcılar Tıp Bülteni 6, no.3 (2021): 287 - 294. 10.4274/BMB.galenos.2021.04.041
MLA TÜFEKCİ SİNAN,KIZILCA OZGUR,ÇELIKKOL ALIYE,Topçu Birol Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. Bağcılar Tıp Bülteni, vol.6, no.3, 2021, ss.287 - 294. 10.4274/BMB.galenos.2021.04.041
AMA TÜFEKCİ S,KIZILCA O,ÇELIKKOL A,Topçu B Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. Bağcılar Tıp Bülteni. 2021; 6(3): 287 - 294. 10.4274/BMB.galenos.2021.04.041
Vancouver TÜFEKCİ S,KIZILCA O,ÇELIKKOL A,Topçu B Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure. Bağcılar Tıp Bülteni. 2021; 6(3): 287 - 294. 10.4274/BMB.galenos.2021.04.041
IEEE TÜFEKCİ S,KIZILCA O,ÇELIKKOL A,Topçu B "Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure." Bağcılar Tıp Bülteni, 6, ss.287 - 294, 2021. 10.4274/BMB.galenos.2021.04.041
ISNAD TÜFEKCİ, SİNAN vd. "Evaluation of Two Consecutive High Sensitivity Cardiac Troponin T Measurements in Healthy Newborns and Newborns with Respiratory Failure". Bağcılar Tıp Bülteni 6/3 (2021), 287-294. https://doi.org/10.4274/BMB.galenos.2021.04.041