Yıl: 2022 Cilt: 22 Sayı: 2 Sayfa Aralığı: 287 - 294 Metin Dili: İngilizce DOI: 10.54614/electrica.2022.210134 İndeks Tarihi: 03-07-2022

Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable

Öz:
In the entire power system operation, the cable is an essential and important component. However, the internal structure of the cable joint is complex and the material has diverse characteristics, which can easily lead to electric field distortion and power failure. Based on this, in order to reduce the occurrence of such problems and improve the safety of cable operation, this paper calculates and analyzes the stress cone parameters of the main insulation layer of a 10 kV cable, and optimizes its structural electric field. Specifically, the formulas of stress cone, reaction force cone, and thickness of the wound-insulating layer are designed, and the parameters are calculated. The results show that the maximum radius Rm of enhanced insulation is 28 mm, the thickness ΔR of enhanced insulation of the cable terminal is 13 mm, etc. The appropriate optimization parameters are then selected, and the electric fields of the shielded pipe structure, stress cone structure, and accessory body are optimized, and a reasonable optimization approach is given
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. L. Guo et al., “Optimization research on improving the distribution of distortion electric field by nonlinear stress control tube of on-board cable terminal,” J. China Railw. Soc., vol. 43, no. 02, pp. 61–70, 2021.
  • 2. J. Wu, Q. D. Shi, S. Li, and C. Y. Wen, “Influence of decentralized coordinated control of doubly-fed units with cable selection on reactive power optimization of wind power plant,” J. Electr. Power Sci. Technol., vol. 35, no. 02, pp. 113–119, 2020.
  • 3. Z. X. Chen et al., “Chen GZ. Research on electric field distribution and structural optimization of integrated prefabricated and wrapped XLPE HVDC cable joints,” J. Harbin Univ. Sci. Technol., vol. 23, no. 06, pp. 77–81, 2018.
  • 4. Z. P. Jiang, J. Y. Song, and W. Yao, “Application of finite element combined with particle swarm optimization and differential evolution algorithm to electric field optimization of cable,” J. Electr. Power, vol. 31, no. 01, pp. 47–52+83, 2016.
  • 5. H. C. Xie, S. Hu, F. X. Huang, and H. Z. Huang, “Typical Fault Case analysis of cable terminal of 10kV ring network cabinet,” Mechan. Electr. Inform., no. 12, pp. 14–16, 2021.
  • 6. H. Wang, and A. Q. Ma, “Simulation and improvement measures of air gap defect of prefabricated stress cone in high temperature superconducting cable terminal,” Hydropower Energ. Sci., vol. 37, no. 08, pp. 180–182, 2019.
  • 7. Z. E. Zhu et al., “Design of stress cone for flexible dc cable accessories,” Insul. Mater., vol. 52, no. 06, pp. 86–91, 2019.
  • 8. T. Xu, C. Jia, and S. Xu, “Research on the size of stress cone for high voltage power accessories -- Taking 500 kV cable as an example,” Commun. Power Technol., vol. 35, no. 06, pp. 41–43, 2018.
  • 9. X. J. Zhou, “Optimization design of multi-interface stress cone for high voltage cable terminal,” Bull. Sci. Technol., vol. 34, no. 05, pp. 180–183, 2018.
  • 10. W. Wang, D. X. He, P. X. Song, X. R. Wang, F. S. Meng, and Q. Q. Li, “Effect of combined electrothermal aging on space charge accumulation characteristics at stress cone of cable accessories,” High Voltage Technol., vol. 45, no. 06, pp. 1737–1744, 2019.
  • 11. J. Y. Zhuo, Design Principle of Power Cable. Beijing: China Machine Press, 1999.
  • 12. Y. Xin, Conducting Power Cables of Superconductors. Beijing: China Electric Power Press, 2013.
APA WU J, XU J, QIN W, WANG J, WU M (2022). Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. , 287 - 294. 10.54614/electrica.2022.210134
Chicago WU Jian,XU Jing,QIN Weixun,WANG Jianfeng,WU Mugen Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. (2022): 287 - 294. 10.54614/electrica.2022.210134
MLA WU Jian,XU Jing,QIN Weixun,WANG Jianfeng,WU Mugen Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. , 2022, ss.287 - 294. 10.54614/electrica.2022.210134
AMA WU J,XU J,QIN W,WANG J,WU M Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. . 2022; 287 - 294. 10.54614/electrica.2022.210134
Vancouver WU J,XU J,QIN W,WANG J,WU M Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. . 2022; 287 - 294. 10.54614/electrica.2022.210134
IEEE WU J,XU J,QIN W,WANG J,WU M "Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable." , ss.287 - 294, 2022. 10.54614/electrica.2022.210134
ISNAD WU, Jian vd. "Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable". (2022), 287-294. https://doi.org/10.54614/electrica.2022.210134
APA WU J, XU J, QIN W, WANG J, WU M (2022). Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. Electrica, 22(2), 287 - 294. 10.54614/electrica.2022.210134
Chicago WU Jian,XU Jing,QIN Weixun,WANG Jianfeng,WU Mugen Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. Electrica 22, no.2 (2022): 287 - 294. 10.54614/electrica.2022.210134
MLA WU Jian,XU Jing,QIN Weixun,WANG Jianfeng,WU Mugen Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. Electrica, vol.22, no.2, 2022, ss.287 - 294. 10.54614/electrica.2022.210134
AMA WU J,XU J,QIN W,WANG J,WU M Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. Electrica. 2022; 22(2): 287 - 294. 10.54614/electrica.2022.210134
Vancouver WU J,XU J,QIN W,WANG J,WU M Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable. Electrica. 2022; 22(2): 287 - 294. 10.54614/electrica.2022.210134
IEEE WU J,XU J,QIN W,WANG J,WU M "Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable." Electrica, 22, ss.287 - 294, 2022. 10.54614/electrica.2022.210134
ISNAD WU, Jian vd. "Parameter Calculation and Structural Electric Field Optimization of Stress Cone for Main Insulation Layer of a 10 kV Cable". Electrica 22/2 (2022), 287-294. https://doi.org/10.54614/electrica.2022.210134