Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center

Öz:
Objective: Arterial pulse-derived cardiac output monitors are routinely employed to guide hemodynamic management during liver transplant surgery. In this study, we sought to assess the reliability by evaluating the agreement of the cardiac output measured by the FloTrac Vigileo versus pulmonary artery catheter (continuous cardiac output) at specified times during liver transplant. Methods: Liver transplant database with cardiac output values measured by FloTrac Vigileo and continuous cardiac output was analyzed retrospectively at a tertiary care hospital. Data were compared at T0: baseline, T1: 1 hour in dissection phase, T2: anhepatic phase, T3: portosystemic shunt, T4: reperfusion, T5: 1 hour after reperfusion, and T6: skin closure. Statistical analysis was done using Bland–Altman analysis and percentage error (<30%) to assess the agreement between cardiac output measured by 2 techniques, Lin’s concordance correlation coefficient for quantifying the agreement and 4-quadrant plots to compare the trends of cardiac output. Results: Bland–Altman analysis showed mean cardiac output ± standard deviation L min-1 (95% CI) at T0: 0.2 ± 2.09 (−3.9 to 4.3), T1: 0.53 ± 3.0 (−5.4 to 6.4), T2: 0.47 ± 2.1(−3.7 to 4.6), T3: 0.31 ± 1.9 (−3.4 to 4.0), T4: 0.44 ± 2.15 (−3.8 to 4.7), T 5:0.69 ± 1.9. (−2.9 to 4.3), and at T6: 0.43 ± 2.25 (−4.0 to 4.8). Percentage error was 44%-72% and concordance correlation coefficient was poor (<0.65) at all points. Conclusions: There is poor agreement between the cardiac output measured by FloTrac and pulmonary artery catheter among liver transplant recipients. The need for superior hemodynamic monitoring is mandated in liver transplant.
Anahtar Kelime:

Belge Türü: Makale Makale Türü: Araştırma Makalesi Erişim Türü: Erişime Açık
  • 1. Kwon HM, Hwang GS. Cardiovascular dysfunction and liver transplantation. Korean J Anesthesiol. 2018;71(2):85-91. [CrossRef]
  • 2. Reddy RV, Agarwal S, Choudhary V, Singhal AK. Reverse stress cardiomyopathy post-liver transplant needing mechanical circulatory support. Indian J Anaesth. 2018;62(12):988-990. [CrossRef]
  • 3. Manecke GR Jr, Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth. 2007;21(1):3-7. [CrossRef]
  • 4. Mayer J, Boldt J, Mengistu AM, Röhm KD, Suttner S. Goaldirected intraoperative therapy based on auto calibrated arterial pressure waveform analysis reduces hospital stay in highrisk surgical patients: a randomized, controlled trial. Crit Care. 2010;14(1):R18. [CrossRef]
  • 5. Camporota L, Beale R. Pitfalls in haemodynamic monitoring based on the arterial pressure waveform. Crit Care. 2010;14(2):124. [CrossRef]
  • 6. De Backer D, Marx G, Tan A, et al. Arterial pressure–based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med. 2011;37(2):233-240. [CrossRef]
  • 7. Biancofiore G, Critchley L, Lee A, et al. Evaluation of a new software version of the FloTrac/Vigileo (Version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery. Anesth Analg. 2011;113:515-522.
  • 8. Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571-582. [CrossRef]
  • 9. Critchley LA, Yang XX, Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth. 2011;25(3):536-546. [CrossRef]
  • 10. Saugel B, Grothe O, Wagner JY. Tracking changes in cardiac output: statistical considerations on the 4-quadrant plot and the polar plot methodology. Anesth Analg. 2015;121(2):514-524. [CrossRef]
  • 11. Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989;45(1):255-268. [CrossRef]
  • 12. Gwak MS, Kim JA, Kim GS, et al. Incidence of severe ventricular arrhythmias during pulmonary artery catheterization in liver allograft recipients. Liver Transpl. 2007;13(10):1451- 1454. [CrossRef]
  • 13. Biais M, Nouette-Gaulain K, Cottenceau V, et al. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg. 2008;106(5):1480-1486. [CrossRef]
  • 14. Nissen P, Van Lieshout JJ, Novovic S, Bundgaard-Nielsen M, Secher NH. Techniques of cardiac output measurement during liver transplantation: arterial pulse wave versus thermodilution. Liver Transpl. 2009;15(3):287-291. [CrossRef]
  • 15. Lee M, Weinberg L, Pearce B, et al. Agreement between radial and femoral arterial blood pressure measurements during orthotopic liver transplantation. Crit Care Resusc. 2015;17(2):101-107.
  • 16. Mayer J, Boldt J, Schöllhorn T, Röhm KD, Mengistu AM, Suttner S. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth. 2007;98(2):176-182. [CrossRef]
  • 17. Chakravarthy M, Patil TA, Jayaprakash K, Kalligudd P, Prabhakumar D, Jawali V. Comparison of simultaneous estimation of cardiac output by four techniques in patients undergoing off-pump coronary artery bypass graft: a prospective observational study. Ann Card Anaesth. 2007;10(2):121-126. [CrossRef]
  • 18. Krejci V, Vannucci A, Abbas A, Chapman W, Kangrga IM. Comparison of calibrated and uncalibrated arterial pressurebased cardiac output monitors during orthotopic liver transplantation. Liver Transpl. 2010;16(6):773-782. [CrossRef]
  • 19. Biancofiore G, Critchley LA, Lee A, et al. Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth. 2009;102(1):47-54. [CrossRef]
  • 20. Rocca GD, Costa MG, Chiarandini P, et al. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions. J Cardiothorac Vasc Anesth. 2008;22(5):681-687. [CrossRef]
  • 21. Metzelder S, Coburn M, Fries M, et al. Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy. Br J Anaesth. 2011;106(6):776-784. [CrossRef]
  • 22. Nishikawa T, Dohi S. Errors in the measurement of cardiac output by thermodilution. Can J Anaesth. 1993;40(2):142-153. [CrossRef]
  • 23. Hamm JB, Nguyen BV, Kiss G, et al. Assessment of a cardiac output device using arterial pulse waveform analysis, Vigileo™, in cardiac surgery compared to pulmonary arterial thermodilution. Anaesth Intensive Care. 2010;38(2):295-301. [CrossRef]
  • 24. Tsai HI, Tsai YF, Yu HP. Arterial waveform monitoring during liver transplantation. Exp Clin Cardiol. 2014;6:145-157.
  • 25. Kim SH, Hwang GS, Kim SO, Kim YK. Is stroke volume variation a useful preload index in liver transplant recipients? A retrospective analysis. Int J Med Sci. 2013;10(6):751-757. [CrossRef]
  • 26. Shah SB, Bhargava AK, Hariharan U, Vishvakarma G, Jain CR, Kansal A. Cardiac output monitoring: a comparative prospective observational study of the conventional cardiac output monitor Vigileo™ and the new smartphone-based application Capstesia ™. Indian J Anaesth. 2018;62(8):584-591. [CrossRef]
  • 27. De Pietri L, Mocchegiani F, Leuzzi C, Montalti R, Vivarelli M, Agnoletti V. Transoesophageal echocardiography during liver transplantation. World J Hepatol. 2015;7(23):2432-2448. [CrossRef]
  • 28. Dalia AA, Flores A, Chitilian H, Fitzsimons MG. A comprehensive review of transesophageal echocardiography during orthotopic liver transplantation. J Cardiothorac Vasc Anesth. 2018;32(4):1815-1824. [CrossRef]
  • 29. Markin NW, Sharma A, Grant W, Shillcutt SK. The safety of transesophageal echocardiography in patients undergoing orthotopic liver transplantation. J Cardiothorac Vasc Anesth. 2015;29(3):588-593. [CrossRef]
  • 30. De Marchi L, Wang CJ, Skubas NJ, et al. Safety and Benefit of Transesophageal Echocardiography (TEE) in liver transplant: a position paper from the Society for the Advancement of Transplant Anesthesia (SATA). Liver Transpl. 2020;26(8):1019- 1029. [CrossRef]
APA Halemani K, Kumar L, N B, Rajan S, Ramamurthi P, Sudhakar A (2022). Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. , 135 - 141. 10.5152/TJAR.2021.1356
Chicago Halemani Kusuma,Kumar Lakshmi,N Bhadrinath,Rajan Sunil,Ramamurthi Pavithra,Sudhakar Abish Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. (2022): 135 - 141. 10.5152/TJAR.2021.1356
MLA Halemani Kusuma,Kumar Lakshmi,N Bhadrinath,Rajan Sunil,Ramamurthi Pavithra,Sudhakar Abish Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. , 2022, ss.135 - 141. 10.5152/TJAR.2021.1356
AMA Halemani K,Kumar L,N B,Rajan S,Ramamurthi P,Sudhakar A Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. . 2022; 135 - 141. 10.5152/TJAR.2021.1356
Vancouver Halemani K,Kumar L,N B,Rajan S,Ramamurthi P,Sudhakar A Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. . 2022; 135 - 141. 10.5152/TJAR.2021.1356
IEEE Halemani K,Kumar L,N B,Rajan S,Ramamurthi P,Sudhakar A "Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center." , ss.135 - 141, 2022. 10.5152/TJAR.2021.1356
ISNAD Halemani, Kusuma vd. "Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center". (2022), 135-141. https://doi.org/10.5152/TJAR.2021.1356
APA Halemani K, Kumar L, N B, Rajan S, Ramamurthi P, Sudhakar A (2022). Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. Turkish Journal of Anaesthesiology and Reanimation, 50(2), 135 - 141. 10.5152/TJAR.2021.1356
Chicago Halemani Kusuma,Kumar Lakshmi,N Bhadrinath,Rajan Sunil,Ramamurthi Pavithra,Sudhakar Abish Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. Turkish Journal of Anaesthesiology and Reanimation 50, no.2 (2022): 135 - 141. 10.5152/TJAR.2021.1356
MLA Halemani Kusuma,Kumar Lakshmi,N Bhadrinath,Rajan Sunil,Ramamurthi Pavithra,Sudhakar Abish Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. Turkish Journal of Anaesthesiology and Reanimation, vol.50, no.2, 2022, ss.135 - 141. 10.5152/TJAR.2021.1356
AMA Halemani K,Kumar L,N B,Rajan S,Ramamurthi P,Sudhakar A Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. Turkish Journal of Anaesthesiology and Reanimation. 2022; 50(2): 135 - 141. 10.5152/TJAR.2021.1356
Vancouver Halemani K,Kumar L,N B,Rajan S,Ramamurthi P,Sudhakar A Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center. Turkish Journal of Anaesthesiology and Reanimation. 2022; 50(2): 135 - 141. 10.5152/TJAR.2021.1356
IEEE Halemani K,Kumar L,N B,Rajan S,Ramamurthi P,Sudhakar A "Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center." Turkish Journal of Anaesthesiology and Reanimation, 50, ss.135 - 141, 2022. 10.5152/TJAR.2021.1356
ISNAD Halemani, Kusuma vd. "Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center". Turkish Journal of Anaesthesiology and Reanimation 50/2 (2022), 135-141. https://doi.org/10.5152/TJAR.2021.1356